KITCHENAID 30"(76 Manuel d'utilisation

Page 17

Advertising
background image

17

To Convert Standard Surface Burners

1. Remove burner cap.

2. Using a T20 TORX

®

screwdriver, remove the burner base.

3. Apply masking tape to the end of a

7 mm nut driver to help

hold the gas orifice spud in the nut driver while changing it.
Press nut driver down onto the gas orifice spud and remove
by turning it counterclockwise and lifting out. Set gas orifice
spud aside.

4. Gas orifice spuds are stamped with a number, marked with

1 color dot, and have a groove in the hex area. Replace the
Natural gas orifice spud with the correct LP gas orifice spud.

Refer to the following chart for correct LP gas orifice spud
placement.

LP Gas Orifice Spud Chart for Standard Surface Burners

5. Place Natural gas orifice spuds in plastic parts bag for future

use and keep with literature package.

6. Replace burner cap.

7. Repeat steps 1-6 for the remaining burners, except for the

TripleTier

®

Flame burner (on some models). See “To Convert

TripleTier

®

Flame Burners” section.

To Convert TripleTier

®

Flame Burners (on some models)

1. Remove burner cap.

2. Remove the burner head using a size T20 TORX

®

screwdriver.

3. Remove the plate on the external gas orifice spud.

IMPORTANT: The TripleTier

®

Flame burner has 2 gas orifice

spuds. Do not forget to change the external gas orifice spud
located under the plate.

4. Apply masking tape to the end of a

7 mm nut driver to help

hold the internal gas orifice spud in the nut driver while
changing it. Press nut driver down onto the internal gas
orifice spud and remove by turning it counterclockwise and
lifting out. Set internal gas orifice spud aside.

5. Use a 7 mm combination wrench to remove the external gas

orifice spud. Turn counterclockwise to remove. Set external
gas orifice spud aside.

6. Replace each Natural gas orifice spud with the correct LP gas

orifice spud. Refer to the following chart for correct LP gas
orifice spud placement.

LP Gas Orifice Spud Chart for TripleTier

®

Flame Burners

7. Replace burner plate, head and cap.

8. Place Natural gas orifice spuds in plastic parts bag for future

use and keep with literature package.

A. Igniter electrode
B. Gas tube opening

C. Burner cap
D. Burner base

A. Groove

Burner Location

Burner Rating

Color

Size

Right front

Left front

Right rear

Left rear

5,000 Btu/h

13,000 Btu/h

10,000 Btu/h

5,000 Btu/h

Red

Green

Blue

Red

0.70 mm

1.10 mm

0.95 mm

0.70 mm

A

B

C

D

A

A. Burner caps
B. Burner heads

C. External gas orifice spud access plate
D. Internal gas orifice spud

A. Plate
B. External gas orifice spud

C. Internal gas orifice spud

Burner Location

Burner Rating

Color

Size

Left front (external
TripleTier

®

burner)

11,800 Btu/h

Brown

1.00 mm

Left front (internal
TripleTier

®

burner)

2,200 Btu/h

Orange

0.42 mm

A

B

C

D

A

B

C

Advertising