36" (91.4 cm) cooktop models – KITCHENAID 8284908 Manuel d'utilisation

Page 11

Advertising
background image

PLUG

NEUTRAL

5/16 WIDE

BLADE

LINE

1/4 WIDE

BLADE

GROUND

ROUND BLADE

GRN OR GRN/Y

GROUND

SURFACE BURNER

VALVE

SWITCHES

120 VAC 60 Hz

1 PHASE

15 OR 20 AMP

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER
AND DANGEROUS OPERATION.

VERIFY PROPER OPERATION AFTER SERVICING.

SURFACE BURNER

IGNITOR

ELECTRODES

YEL OR BRN

4 PLCS

GRILLE

VALVE

SWITCH

GRILLE

IGNITOR

GRILLE

VALVE

SPARK

MODULE

W

BK

W

BK

W

BK

W

BK

BK

SWITCHES ON SURFACE

BURNER VALVES:

ELECTRIC CIRCUIT

CLOSED

WHEN KNOB IS ROTATED 55

°

TO 95

°

COUNTER CLOCKWISE

FROM OFF

SWITCH ON GRILLE VALVE:

BK

BK RIB

ELECTRIC CIRCUIT

CLOSED

WHEN KNOB IS ROTATED 20

°

TO 360

°

COUNTER CLOCKWISE

FROM OFF

THE POWER CORD ON THIS APPLIANCE IS EQUIPPED WITH A 3-PRONG GROUND PLUG WHICH MATES WITH STANDARD 3-PRONG
GROUND-TYPE OUTLET.

PLUG

GROUND

ROUND BLADE

GRN OR GRN/Y

GROUND

SURFACE BURNER

IGNITOR

ELECTRODES

GRIDDLE

THERMOSTAT

GRIDDLE

IGNITOR

GRIDDLE

VALVE

SPARK

MODULE

W

BK

BK

W

BK

BK RIB

W

BK

W

BK

BK

120 VAC 60 Hz

1 PHASE

15 OR 20 AMP

NEUTRAL

5/16 WIDE

BLADE

LINE

1/4 WIDE

BLADE

SURFACE BURNER

VALVE

SWITCHES

YEL OR BRN

4 PLCS

SWITCHES ON SURFACE

BURNER VALVES:

ELECTRIC CIRCUIT

CLOSED

WHEN KNOB IS ROTATED 55

°

TO 95

°

COUNTER CLOCKWISE

FROM OFF

PLUG

GROUND

ROUND BLADE

GRN OR GRN/Y

GROUND

BLK

WHT

CONNECT

.250 TERMINALS

120 VAC 60 Hz

1 PHASE

15 OR 20 AMP

IGNITOR

ELECTRODES

WHT

SPARK

MODULE

YEL OR BRN

6 PLCS

WHT

WHT

BLK

SWITCHES ON SURFACE

BURNER VALVES:

ELECTRIC CIRCUIT

CLOSED

WHEN KNOB IS ROTATED 55

°

TO 95

°

COUNTER CLOCKWISE

FROM OFF

NEUTRAL
5/16 WIDE
BLADE

LINE

1/4 WIDE

BLADE

VALVE

SWITCHES

SURFACE BURNER

6 surface burners

4 surface burners with grille

4 surface burners with griddle

11

36" (91.4 cm) cooktop models

Advertising