Warning, Make gas connection – KITCHENAID W10154991A Manuel d'utilisation

Page 16

Advertising
background image

16

2. Connect the bare ground wire to the range using the ground-

link screw and cup washer. The ground wire must be
attached first and must not contact any other terminal.

3. Loosen (do not remove) the hex washer head screw and

insert the neutral (white) wire under the screw clamp at the
bottom of the center position terminal connector.

4. Insert the other 2 wires (lines 1 and 2) under the other 2 screw

clamps.

5. Securely tighten the hex washer head screws to

35 lbs-in. (4.0 N-m) minimum torque to make proper
electrical connection.

6. Tighten the locking ring of the conduit connector.

7. Replace the terminal block cover with screw.

3-wire connection: Direct Wire

Use this method only if local codes permit connecting ground
conductor to neutral supply wire.

1. Loosen (do not remove) the hex washer head screws and

insert the neutral (white) wire under the screw clamp at the
bottom of the center position terminal connector.

2. Insert the other 2 wires (lines 1 and 2) under the other 2 screw

clamps.

3. Securely tighten the hex washer head screws to

35 lbs-in. (4.0 N-m) minimum torque to make a proper
electrical connection.

4. Tighten the locking ring of the conduit connector.

5. Replace the terminal block cover with screw.

Make Gas Connection

Typical rigid pipe connection

A combination of pipe fittings must be used to connect the range
to the existing gas line. Your connections may be different,
according to the supply line type, size and location.

1. Apply pipe-joint compound made for use with LP gas to all

pipe thread connections.

A. Bare wire from power

supply cable

B. Line 1

C. Hex washer head screw
D. Silver-colored terminal

block screw

E. Line 2
F. Neutral (white) wire

G. UL listed conduit

connector and power
supply cable

A. Insert wire under screw clamp.
B. Hex washer head screw

A. Line 1
B. Ground-link

C. Hex washer head screw
D. Silver-colored terminal

block screw

E. Neutral (white) wire

F. Line 2

G. UL listed conduit

connector and power
supply cable

A

B

C

D

E

F

G

A

B

A

B

C

D

E

F

G

A. Insert wire under screw clamp.
B. Hex washer head screw

A

B

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.

Examples of a qualified person include:

licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.