Electrical requirements, Installation, Warning – KITCHENAID 8302472A Manuel d'utilisation

Page 5

Advertising
background image

4.

Carefully move range close to the

cabinet opening. Place the rack in oven.
Place level on rack, first side to side; then
front to back.

If the range is not level, adjust the feet
up or down. Turn leveling leg sleeves to
level range and to raise or lower range to
the desired countertop height.

5

remove
screws

bottom
vent

leveling leg
sleeves

Electrical requirements

F.

Connection at connection block must

be copper wire only.

If the house has aluminum wiring, follow
the procedure below:

a) Connect the aluminum wiring to the

copper wiring using special connectors
designed and Underwriters
Laboratories-listed for joining copper
to aluminum. Follow the electrical
connector manufacturer’s
recommended procedure.

b) Aluminum/copper connection must

conform with local codes and industry-
accepted wiring practices.

Copies of the standards listed may be
obtained from:

* National Fire Protection Association

One Batterymarch Park
Quincy, Massachusetts 02269

** CSA International

8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path and wire gauge are in
accordance with local codes.

Do not ground to a gas pipe.

Check with a qualified electrician if you
are not sure the range is properly
grounded.

Do not have a fuse in the neutral or
ground circuit.

This range must be connected to a
grounded metal, permanent wiring
system.

A.

A four-wire or three-wire, single

phase, 240-volt, 60-Hz, AC-only electrical
supply is required on a separate,
50 amp circuit, fused on both sides of the
line. A time-delay fuse or circuit breaker
is recommended. The fuse size must not
exceed the circuit rating of the range
specified on the model/serial rating plate
located on the horizontal surface below
the control panel.

B.

Wire sizes and connections must

conform to the requirements of the
National Electrical Code ANSI/NFPA 70 –
latest edition*, or CSA Standards C22.1-
94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 - latest edition** and all
local codes and ordinances.

C.

The range should be connected

directly to the fused disconnect or circuit
breaker box through flexible, armored or
non-metallic sheathed, copper cable. The
flexible, armored cable extending from
the fuse box or circuit breaker box
should be connected directly to the
junction box.

D.

Locate the junction box to allow as

much slack as possible between the
junction box and the range so that the
range can be moved if servicing is ever
necessary. Do not cut the conduit.

E.

A U.L.- or CSA-listed conduit

connector must be provided at each end
of the power supply cable (at the range
and at the junction box).

Installation

1.

Remove shipping materials, tape

and protective film from range. Keep
shipping pallet under range. Unpack the
burner grates, burner caps, simmer plate,
grille grate, drip tray, spill guard, wave
tray, wave plate, tile bezels, regulator,
backguard and island trim. Items are
either packaged in the range or on the
range. Parts shipped with range depend
on model ordered.

2.

Remove the two side trim pieces by

removing the 4 screws (2 per side).
Remove the bottom vent by removing
the 4 screws (2 on the top and 2 on the
side of the bottom vent). Slide the vent
down and pull toward you. Carefully lay
the parts to the side to avoid scratching
the stainless steel.

3.

Lay a piece of cardboard from side

packing on the floor behind range. Using
2 or more people, firmly grasp each side
of range. Lift range up about 3 inches (8
cm) and move it back until the range is
off shipping pallet. Set range on
cardboard to avoid damaging floor.

5.

Choose the correct bracket for your

installation.

• If the wall behind the range has no

baseboard or a baseboard up to 3/8"
(9.5 mm) thick, use the shorter 1"
(2.5 cm) anti-tip bracket.

• If the wall behind the range has a

baseboard thicker than 3/8" (9.5 mm),
use the longer 1-3/4" (4.4 cm) anti-tip
bracket.

Locate a stud in wall behind range.
Measure distance from top of rear brace
to floor. Add 5/16" (7.9 mm) to
measurement to allow anti-tip bracket to
slide over rear brace. Use this final
measurement and mark a horizontal line
on wall where stud is located.

write down
this distance

rear
brace

WARNING

Excessive Weight Hazard

Use two or more people to move and
install range.

Failure to do so can result in back or
other injury.