Product dimensions

Vent system
requirements

Do not terminate the vent system
in an attic or other enclosed area.
Do not use 4" (10.2 cm) laundry-
type wall caps.
Use metal vent only. Rigid metal
vent is recommended. Do not use
plastic or metal foil vent.
Flexible vent is not
recommended. Flexible vent
creates back pressure that greatly
reduces the hood's performance.

Vent system needed for
installation is not included. 3-1/4"

x

10" (8.3 cm x 25 cm) rectangular is
recommended.

Venting methods

Recommended standard
fittings

3-1/4" x 10"
(8.3 cm x 25 cm)
90° elbow
= 5 ft. (1.5 m)

3-1/4" x 10"
(8.3 cm x 25 cm)
flat elbow
= 12 ft. (3.7 m)

3-1/4" x 10"
(8.3 cm x 25 cm)
wall cap
= 0 ft. (0 m)

Roof venting

3-1/4" x 10"
(8.3 cm x 25 cm)
vent through
the roof

Wall venting

3-1/4" x 10"
(8.3 cm x 25 cm)
vent through
the wall

wall
cap

3-1/4" x 10”
(8.3 cm x 25 cm)
90° elbow

wall
cap

Maximum length

= 26 ft. (8 m)

1 — 90° elbow

= 5 ft. (1.5 m)

9 ft. (2.8 m) straight

= 9 ft. (2.8 m)

1 — wall cap

= 0 ft. (0 m)

Length of 3-1/4" x 10"
(8.3 cm x 25 cm)
system = 14

ft.

(4.3

m)

6 ft. (1.8 m)

3 ft.

(0.93 m)

3-1/4" x 10" (8.3 cm x 25 cm)

vent system

Recommended vent system
length

Use 3 1/4" x 10" (8.3 cm x 25 cm)
vent with maximum length of
26 feet (8 m) for vent system. For
best performance, use no more
than three 90° elbows. To calculate
the length of system you need,
add the equivalent feet (meters)
for each vent piece used in the
system. See the following
example.

7-3/4"

(19.6 cm)

9-15/16"

(25.2 cm)

3-3/16"

(8.1 cm)

Note: Underside of hood must be a minimum of
24" (61 cm) from cooking surface.

2-11/32"

(6.0 cm)

1-3/4"

(4.4 cm)

Do not

use these

knockouts

1-13/16"

(4.6 cm)

2-9/16"

(6.5 cm)

1-9/16"

(4.0 cm)

1-3/16"

(3.0 cm)

1-3/16"

(3.0 cm)

4-3/4"

(12.1 cm)

5-1/16"

(12.9 cm)

9-27/32"

(25.0 cm)

17-3/4"

(45.1 cm)

13-3/8"

(34.0 cm)

30" (76.2 cm)
36" (91.4 cm)

For vented models:

• The size of the vent should be

uniform.

• Use no more than three 90°

elbows.

• Make sure there is a minimum

of 24" (61 cm) of straight vent
between the elbows if more
than one elbow is used.

• Do Not install two elbows

together.

• The length of vent system and

number of elbows should be
kept to a minimum to provide
efficient performance.

• The vent system must have a

damper. If roof or wall cap has
a damper, Do Not use damper
supplied with the range hood.

• Use duct tape to seal all joints

in the vent system.

• Use caulking to seal exterior wall

or roof opening around the cap.

Note: It is recommended that the
vent system be installed before
installing the hood.

Roof-vented model shown.