Warning, Attach backguard or island trim – KITCHENAID 9759121A Manuel d'utilisation

Page 10

Advertising
background image

10

4-Wire Cable from Power Supply

IMPORTANT: Use the 4-wire cable from power supply where
local codes do not permit connecting the frame-ground
conductor to the neutral (white) junction box wire.

1. Disconnect power.

2. Remove junction box cover if present.

3. Connect the 4-wire flexible cable from the range to the

junction box using a UL listed or CSA approved conduit
connector.

4. Tighten screws on conduit connector if present.

5. Connect the 2 black wires together using the UL listed wire

connectors.

6. Connect the 2 white wires together using the UL listed wire

connectors.

7. Connect the green or bare ground wire from the range cable

to the green or bare grounded wire (in the junction box) using
the UL listed wire connectors.

8. Install junction box cover.

9. Reconnect power.

3-Wire Cable from Power Supply

IMPORTANT: Use the 3-wire cable from power supply where
local codes permit connecting the frame-ground conductor to
the neutral (white) junction box wire (not used for Canadian
installations).

1. Disconnect power.

2. Remove junction box cover if present.

3. Connect the 4-wire flexible cable from the range to the

junction box using a UL listed or CSA approved conduit
connector.

4. Tighten screws on conduit connector if present.

5. Connect the 2 black wires together using UL listed wire

connectors.

6. Connect the 2 red wires together using UL listed wire

connectors.

7. Connect the green (or bare) and white range cable wires to

the white (neutral) wire in the junction box using UL listed
wire connectors.

8. Install junction box cover.

9. Reconnect power.

Attach Backguard or Island Trim

1. Using 2 or more people, move range close to cabinet

opening.

2. Remove cardboard or hardboard from under range. Move

range into it’s final location.

3. Attach the backguard or island trim as required for your

installation. See “Tools and Parts.” Attachment screws are
included in the literature package.

A. Cable from power supply
B. Red wires

C. Green (or bare) ground wires
D. 4-wire flexible cable from range

E. Junction box

F. White wires

G. UL listed wire connectors
H. Black wires

I. UL listed or CSA approved

conduit connector

A
B

C

D

E

F

G

H

I

A. Cable from power supply
B. Junction box

C. Red wires
D. White wire (from power supply)

E. Green (or bare) grounding wires

(from range)

F. White wire (from range)

G. 4-wire flexible cable from

range

H. Black wires

I. UL listed wire connectors

J. UL listed or CSA

approved conduit
connector

B

C

D

E

F

H

G

A

I

J

WARNING

Excessive Weight Hazard

Use two or more people to move and install range.

Failure to do so can result in back or other injury.

Advertising