Installation requirements, Tools and parts, Location requirements – KITCHENAID 9760425A Manuel d'utilisation

Page 4

Advertising
background image

4

Product Dimensions

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Island hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.

Grounded electrical outlet is required. See “Electrical
Requirements” section.

It is recommended that the hood be fastened into solid wood.

The island hood is factory set for venting through the roof or wall.
For recirculating installations see “Recirculating Installations” in
“Install Chimney Covers” section.

All openings in ceiling and where island hood will be installed
must be sealed.

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools
listed here.

Tools needed:

level

drill with 1

¹⁄₄" (3.0 cm) drill bit

pilot hole drill bit (determined by chimney support
attachment method)

pencil

wire stripper or utility knife

measuring tape or ruler

pliers

caulking gun and weatherproof caulking compound

duct tape

jig saw or keyhole saw

flat blade screwdriver

metal snips

Phillips screwdriver

Parts needed:

2 UL- or CSA- listed,

¹⁄₂" (12.5 mm) strain reliefs

power supply cable

1 wall or roof cap

metal vent system

4, concrete anchors for

¹⁄₄" x 4" hex head lag bolts if

installing into concrete

Parts supplied:

Remove parts from packages. Check that all parts were included.

hood canopy assembly with ventilator and light bulbs installed

chimney assembly

ceiling template

Installation Instructions and Use & Care Guide

3 filters

hardware package (4 wood shelf bolts, 4 wood shelf bolt
washers, 4 wood shelf nuts, 4 concrete plugs, 1 mounting
template, 1 damper)

INSTALLATION REQUIREMENTS

23

⁵⁄₈

"

(60.0 cm)

13

³⁄₄

"

(34.9 cm)

12

¹⁄₁₆

"

(30.6 cm)

4

³⁄₄

"

(12.1 cm)

35

³⁄₈

" (89.9 cm)

27

¹⁄₂

"

(69.9 cm)

26

³⁄₈

" (65.1 cm)

min.

39" (99.1cm)

max.

23

⁵⁄₈

"

(60.0 cm)

12

¹⁄₂

"

(31.8 cm)

3

¹⁄₂

"

(8.9 cm)

5"

(12.7 cm)

13

³⁄₄

"

(34.9 cm)

12

¹⁄₁₆

"

(30.6 cm)

32" (81.3 cm)

min.

39" (99.1 cm)

max.

Recirculating chimney kit dimensions

For recirculating installations, optional Recirculating Chimney Kit
No. 4396911 (Stainless Steel) or Kit No. 4396912 (Meteorite) must
be used. These kits include a new lower chimney cover (that
replaces the lower chimney cover shipped with the island hood),
a charcoal filter and a diverter.