Troubleshooting

OUOD006,000001E

–19–17JUN04–1/1

Troubleshooting Battery Charger

Symptom

Problem

Solution

Battery connected and charger

Charger in tester mode, not charger

Press CHARGE RATE button to

on, but battery not charging.

mode.

activate charger, and select a charge
rate.

Indicator lights illuminate in an

Charger in a special diagnostic

Make sure nothing is touching the

erratic manner not explained in

mode.

control panel, then unplug the unit

“Controls and Operation”

and plug it in again.

section.

Charger defective.

Return unit to place of purchase for
replacement.

The CHECK (red) light flashes

Incorrect battery type selected.

Reset charger by briefly unplugging

before battery is completely

it or briefly disconnecting the battery

charged.

clamp to ground, and select proper
charge rate and battery type.

Battery did not reach full charge in

Reset charger by briefly unplugging

24 hours.

it or briefly disconnecting the battery
clamp to ground, and select proper
charge rate and battery type.

Engine crank time is less than

Starter motor drawing more than 100

Charge battery at 40A rate for 10 to

specified.

amps.

15 minutes, then crank the engine.

The CHARGED (green) light

Battery voltage high enough for

Turn headlights on for a few minutes

illuminates a few minutes after

battery to appear to be fully charged.

to reduce battery voltage and try

connecting charger to battery.

charging again.

Incorrect battery type selected.

Reset charger by briefly unplugging
it or briefly disconnecting the battery
clamp to ground, and select proper
charge rate and battery type.

15-1