Mr. Heater HS35LP Manuel d'utilisation

Page 2

Advertising
background image

CLEARANCE (Minimum clearances to combustible materials)

MODEL NO.

BTU/HR RATING

NORMAL OPERATING

CLEARANCES TO

TYPE GAS

POSTION

COMBUSTIBLES

NATURAL

LP & NG

TOP

SIDES

BACK

FRONT

35LP

35,000*

VERTICAL

40”

40”

0”

54”

CONTENTS

Installation Instructions .................................................... 3

Location .......................................................................... 3

Piping .............................................................................. 3

Operating Instructions ..................................................... 4

Lighting and Shut Down .................................................. 4

Maintenance Instructions ................................................ 5

Replacement Parts List ..................................................... 6

Service and Parts Ordering Information ........................... 8

The heater is designed and approved for use as a construction
heater under ANSI Z83.7 / CGA 2.14 - 2000

We cannot anticipate every use which may be made of our
heaters. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF
YOU HAVE QUESTIONS ABOUT APPLICATIONS.

Other standards govern the use of fuel gases and heat producing
products in specific applications. Your local authority can advise
you about these.

This appliance is intended to be used primarily for the heating of
buildings under construction, alteration or repair.

FOR YOUR SAFETY

Do not use this heater in a space where
gasoline or other liquids having flammable
vapors are stored or used.

WARNING

DO NOT EXCEED 27.5” W.C. (1 psi) INLET
PRESSURE TO HEATER.

SPECIFICATIONS

MODEL NO. ............... 35LP

35LP

GAS TYPE ................ LP-Gas

MAX. INLET
PRESSURE. ......... 27.5” W.C.

MIN. INLET
PRESSURE .......... 27.5” W.C.

MANIFOLD
PRESSURE .......... 25.5” W.C.

VENTILATION

WARNING

THIS APPLIANCE IS UNVENTED AND MUST BE
USED ONLY IN A WELL VENTILATED AREA.

The flow of combustion and ventilation air must not be
obstructed. DO NOT use in a tightly enclosed area. Any
combustion process requires and consumes oxygen, and may
produce carbon monoxide. This heater must be operated with
adequate ventilation. Two openings directly to the outdoors must
be provided, one low and one high, preferably on opposite sides
of the area to be heated. Each of these openings must provide at
least three square inches of combustion air-intake area and
exhaust outlet area for every 1000 BTUs per hour of heater input
rate in order to complete the combustion/ventilation process.
Provide additional ventilation for any additional fuel-burning
appliances and/or additional occupants.

Do not exceed the gas supply pressures shown on rating plate
for Model 35LP. The maximum inlet gas supply pressure and the
minimum inlet gas supply pressure (for purposes of input
adjustment) for LP-Gas are shown as follows:

*Tank size and tank temperature can directly affect BTU output

THE STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNING:

WARNING

Combustion by-products produced when using this product contain
carbon monoxide, a chemical known to the State of California to
cause cancer and birth defects (or other reproductive harm).

2

Operating Instructions and Owner’s Manual

Enerco Group, Inc. | Gas-Fired Infra-Red Portable Construction Heater