General machine description, Commissioning, Symbols used – Metabo Welding Machine MIG/MAG 140 Manuel d'utilisation

Page 5: Taking out of enclosed parts, Installation conditions, Mains connection, Shielding gas cylinder connection

Advertising
background image

1.3

MIG/MAG 140/160

x Switch the unit off for longer work breaks.

Unplug when work is completed and before relo-
cating the unit. In case of accidents separate the
welding power source at once from the power
supply.

General Machine Description

The MIG/MAG welding machine consists of a trans-
former (static characteristic curve), a series-con-
nected silicon rectifier, a welding circuit choke, and
a wire feed unit.

The welding machine is suitable for the welding of
different electrode wires (e.g. steel, see "Technical
Specifications") under a shielding gas cover (CO2,
mixed gas and argon).

The machine is fan cooled and has an overload pro-
tection.

Symbols Used

Danger!



Disregard of the following warnings
could cause serious personal injury
or material damage.

Read operating instructions before
initial operation

Wire feed speed

Do not use in rain.

Welding machine suitable for welding in
environments with an increased electri-
cal hazard.

Excess temperaturer

Information on the name plate:

Commissioning

Taking out of enclosed parts

All enclosed parts are inside the wire feed compart-
ment and can be taken out after the wire feed com-
partment cover is removed..

Installation Conditions

x The protective gas welding unit must be

installed in a dry environment with sufficient
room for cooling.

x If the unit is placed on an inclined surface it must

be secured against falling: place the unit on a
suitable level support surface.

x The unit is designed for use in covered areas.

Welding outside in the rain is not permitted.

Mains connection

x Check to see that mains voltage matches the

voltage shown on the machine's rating plate.

x Set welding step switch to "0" before plugging

in.

Shielding gas cylinder connection

x Place gas cylinder onto the welding machine's

cylinder rack and secure with the chain to the
cylinder holder at the rear of the unit. Take off
the cylinder cap and open cylinder valve briefly,
facing away from your body.

x Screw pressure reducer to the gas cylinder

valve. Run gas hose from pressure reducer to
gas inlet port of the unit.

x Recommended gas flow rate in draft-free

rooms: 5-10 l/min.

7

8

9

10

12

13

6

11

6

Manufacturer

7

Machine designation

8

Serial number

9

Standard information – This machine meets
the requirements of the standards mentioned

10

CE mark – This machine conforms to EC
directives as per declaration of conformity

11

Waste disposal symbol – the machine can be
disposed of through the manufacturer

12

Electrical performance data

13

Date of manufacture

Advertising