Warning, Electrical connection - u.s.a. only – Maytag Bravos W10163136A Manuel d'utilisation

Page 8

Advertising
background image

8

Electrical Connection - U.S.A. Only

1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.

Power Supply Cord

Direct Wire

WARNING

Fire Hazard

Use a new UL listed 30 amp power supply cord.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center
terminal (silver).

Ground wire (green or bare wire) must be connected to
green ground connector.

Connect remaining 2 supply wires to remaining
2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or
electrical shock.

WARNING

Fire Hazard

Use 10 gauge solid copper wire.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center
terminal (silver).

Ground wire (green or bare wire) must be connected to
green ground connector.

Connect remaining 2 supply wires to remaining
2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or
electrical shock.

A. Terminal block cover

B. External ground conductor

screw

C. Center, silver-colored

terminal block screw

D. Hold-down screw location

E. Neutral ground wire
F. Hole below terminal block

opening

A B

E

F

C

D