Installation instructions, Warning, Wire system for electric dryers – GE PSXH43 Manuel d'utilisation

Page 17

Advertising
background image

NOT for use in Canada.
DO NOT use for Mobile Home Installations.
NOT for use on new construction.

1.

Remove the screws securing the terminal block access

cover and the strain relief mounting bracket located on
the back of the dryer upper corner.

2.

Install a UL-listed strain relief into the power cord entry

hole of the mounting bracket. Finger-tighten the nut
only at this time.

3.

Thread a UL-listed 30A, 240V, 3 #10 AWG minimum
copper conductor power cord through the strain relief.

4.

Attach the power cord neutral (center wire) conductor
to the silver-colored center terminal on the terminal
block. Tighten the screw securely.

5.

Attach the remaining two power cord outer conductors
to the outer brass-colored terminals on the terminal
block. Tighten both screws securely.

WARNING:

Do not make a sharp bend or

crimp wiring/conductor at connections.

6.

Reattach the strain relief mounting bracket to the
back of the dryer with screws provided. Tighten screws
securely.

7.

Tighten the screws securing the cord restraint firmly
against the power cord.

8.

Tighten the strain relief nut securely so that the strain
relief does not turn.

9.

Reinstall the terminal block access cover.

3-WIRE SYSTEM FOR
ELECTRIC DRYERS

Installation Instructions

17

Green ground screw

Silver terminal

Nut

Tighten nut to
these threads

Power cord

Strain relief

mounting bracket

Green neutral
ground wire

Use copper

conductors only.

Effective January 1, 1996:

The National Electrical Code

requires that new construction (non existing) utilize a
4-wire connection to an electric dryer.
In Canada a 4-wire power supply cord is installed on
the dryer.
1.

Remove the screws securing the terminal block access
cover and the strain relief mounting bracket located on
the back of the dryer upper corner.

2.

Install a UL-listed strain relief in the entry hole of
the mounting bracket. Finger-tighten the nut only
at this time.

3.

Remove the green neutral ground wire from the green
ground screw located above the terminal block.

4.

Thread a UL-listed 30A, 240V, 4 #10 AWG minimum
copper conductor power cord through the strain relief.

5.

Attach the green power cord ground wire to the
cabinet with the green ground screw.

6.

Attach the white (neutral) power cord conductor from
the power cord and the green ground wire from the
dryer harness to the silver-colored center terminal on
the terminal block. Tighten the screw securely.

7.

Attach the red and black power cord conductors to the
outer brass-colored terminals on the terminal block.

WARNING:

Do not make a sharp bend

or crimp wiring/conductor at the connections.

8.

Tighten the screws securing the cord restraint firmly
against the power cord.

9.

Tighten the strain relief nut securely so the strain relief
does not turn.

10.

Reinstall the terminal block access cover.

4-WIRE SYSTEM FOR
ELECTRIC DRYERS

Typical 4
conductor
receptacle

Black 240V

White neutral

Red 240V

Green ground

Typical
4 conductor cord

Green ground
screw

Green neutral
ground wire

Red

White

Black

Terminal block

Silver terminal

Green power cord ground wire

Nut

Tighten nut to
these threads

Power cord

Strain

relief

mounting

bracket