Lp conversion, Making the l.p. conversion, Cont – GE JGP328 Manuel d'utilisation

Page 14: Changing the cooktop burner orifices

Advertising
background image

14

LP Conversion

F3

Changing the Cooktop
Burner Orifices:

a. Remove the top grates, burner caps,

burner heads and
burner bases.

II

II

I

II

b. Remove the electrodes

from the burner base.
Using a No. 15 “Torx”
head driver bit, remove
the screws holding the
burner base in position.

c. Using a 7mm or 9/32"

nut driver, remove the
top burner orifices.
These may be
accessed through the hole in the cooktop.

NOTE: The orifices have a spring loaded
retaining ring around the hex head to hold
the orifice in the nut driver
during installation and
removal. A slight amount
of force is required to
push the nut driver down
over the ring.

RETAINER
RING

d. Locate the LP/Propane orifices shipped

inside the literature package. They will have
a digit number and the letter “L” on the side.
(Important: Save the orifices removed
from the appliance for future use.)
Each orifice will show a series of engraved
marks, (i, II, III or X), located on the top.

I

II

III

X

These marks denote the precise location of
each orifice to the cooktop burner.

Units with 1500 BTU/HR burner on right front.
(See rating plate on bottom of appliance.)

III

II

I

X

Units with 9100 BTU/HR burner on right front.
(See rating plate on bottom of appliance.)

e. Install the LP/Propane orifices in their

precise locations as noted in the illustrations
above.

f. Return the natural orifices to the bracket and

reattach the bracket and the instruction
sheet to the pressure regulator using the
screw previously removed.

g. Replace the burner bases, heads, caps and

top grates. (Note: When re-attaching the
burner bases to glass top units, tighten
screws to a maximum of 10 in.-lbs torque.)

continued on following page

ORIFICE SPUD

LOCATED THRU

THIS OPENING

REMOVE

THIS

ASSEMBLY

Making the L.P. Conversion

cont.

F

Advertising