Version 03/08 - Page 6

PLAN YOUR DUCTWORK

To ensure that the blower performs to its highest

possible capacity, ductwork should be as short

and straight as possilbe.

The ductrun should not exceed 55 equivalent

feet if ducted using the required minimum of

10" round duct. Calculate the length of the

ductwork by adding the equivalent feet in

FIG-

URE 2 for each piece of duct in the system An

example is given in

FIGURE 3.

For best results, use no more than three 90°

elbows. Make sure that there is a minimum of

24" of straight duct between elbows if more

than one is used. Do not install two elbows

together. If you must elbow right away, do it

as far away from the hood's exhaust opening

as possible.

9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap
Total System

9.0 feet

10.0 feet

0.0 feet

19.0 feet

FIGURE 3

3.0 feet
5.0 feet

12.0 feet

0.0 feet

45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap

FIGURE 2

MAKE YOUR CUT-OUTS

1. Disconnect and move freestanding range from cabinet opening to provide easier access

to upper cabinet or custom hood. Put a thick, protective covering over cooktop, set-in

range or countertop to protect from damage or dirt.

2. Determine and clearly mark with a pencil the center line on the cabinet or custom hood

where the rangehood will be installed.

3. Determine and make all necessary cuts in the wall and/or ceiling for the ductwork.

Install the ductwork before the rangehood.

4. Determine the proper location for the Power Supply Cable. Use a 1

1/4"

Drill Bit to make

this hole. Install the cable. Use caulking to seal around the hole. DO NOT turn on the

power until installation is complete.

5. Make the cut-out opening where the rangehood will be installed (FIGURE 4).

FIGURE 4

28 7/8"

14 5/8"

CUT-OUT

ATTENTION

This rangehood is designed to be connected to a remote blower (pur-

chased separately). CAUTION: To reduce the risk of fire and electric

shock, install this rangehood only with remote blowers rated a maxi-

mum 1.8 Amp, suitable for use with solid state fan speed controls. The

remote blower requires a separate wiring cable that should be installed

at the same time that the ductwork is installed. For best results, 10”

duct is recommended for the remote blower.

INSTALL THE RANGEHOOD

1. Remove the rangehood , as seen in (FIGURE 5) from the carton

and place on a flat surface. Cover the surface to prevent accidental

damage. Remove all parts including the literature package before

discarding the carton.

FIGURE 5