Warning, Figure 3 - flat roof installations, Figure 4 - electrical connections – Faber 1200 CFM Manuel d'utilisation

Page 4: Warranty & service

Advertising
background image

Version 05/06 - Page 4

1. Remove the cover from the remote blower. Then remove the

wiring box cover.

2. Pull electrical wiring through the hole in the blower base and

secure it according to local codes.

3. Make the electrical connections. Connect the white and black

wires of the power supply cable wire to the white and black wires

in the wiring box with twist-on connector. Connect the green power
supply ground wire to the green ground screw.

4. Replace the wiring box cover and screws taking care not to pinch

the wiring under the wiring box cover.

5. Turn on power (See Installation Instructions that came with your

vent hood system). Check operation of blower and make sure damper

is opening freely.

6. Reinstall remote blower housing.

Flat roof installations

Make the duct & electrical connections

wiring diagram

You can be killed or seriously injured if you don’t follow

instructions.

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR

INJURY TO PERSONS, OBSERVE THE FOLLOWING:

• Disconnect power before making electrical connection.

• Connect the ground wire to green ground screw in wiring box.

Failure to do so can result in death or electrical shock.

WARNING

Figure 3 - Flat roof installations

1. Locate the 11" (27.9 cm) dia. hole between rafters.

2. Build a sloping base that will mount the remote blower at a

minimum pitch of 2-1/2" (6.4 cm).

3. Weatherproof the base as required.

4. Locate the base so that the remote blower’s vent aligns with the

11" (27.9 cm) dia. hole and the blower sits evenly on the base with
no gaps. Note: Make sure that the discharge end of the remote
blower faces away from the direction of prevailing winds.

5. Use dimensions from either FIGURE 1 or 2 to locate the 1-1/4"

(3.0 cm) dia. wiring hole. CONTINUE WITH POINT

6 UNDER

ROOF INSTALLATIONS ON PAGE 3.

Figure 4 - Electrical connections

!

Warranty & Service

All Faber products are warranteed against any defect in materials or work-

manship for the original purchaser for a period of 1 year from the date of

original purchase. This warranty covers labor and replacement parts. The

warranty does not cover consumable parts such as filters and light bulbs.

This warranty does not apply if this product has been subjected to faulty

installation, misuse, or neglect. This warranty excludes any consequential

expense or damage resulting from any use or malfunction of the product.

All implied warranties are limited to the duration of this warranty.

To obtain warranty service, contact the dealer from whom you purchased

the rangehood, or the local Faber distributor. If you cannot identify a local

Faber distributor, contact us at (508) 358-5353 for the name of a distributor

in your area.

Advertising