INSTALLATION REQUIREMENTS

IMPORTANT

DO NOT INSTALL YOUR WASHER:
1 In an area exposed to dripping water or outside

weather conditions. The ambient temperature

should never be below 60° F (15.6° C) to

maximize detergent effectiveness.

2 In an area (garage or garage-type building)

where gasoline or other fl ammables (including

automobiles) are kept or stored.

3 On carpet. Floor MUST be solid with a maximum

slope of 1 inch (2.54 cm). To minimize vibration

or movement, reinforcement of the fl oor may be

necessary.

MINIMUM INSTALLATION CLEARANCES - Inches (cm)

SIDES

REAR

TOP

FRONT

Alcove

0” (0 cm) 0” (0 cm)* 0” (0 cm)

n/a

Under-
Counter

0” (0 cm) 0” (0 cm)* 0” (0 cm)

n/a

Closet

0” (0 cm) 0” (0 cm)* 0” (0 cm)

1” (2.5 cm)

0”

(0cm)

0”

(0cm)

1”

(2.5cm)

0”

(0cm)

Installation in a Recess or Closet

If washer and dryer are installed in the same closet,

door ventilation is required: A minimum of 120 square

inches (774.2 cm²) of opening, equally divided at the top

and bottom of the door, is required. Louvered openings

should be located 3 inches (7.6 cm) from bottom and

top of door. Air openings are required to be unobstructed

when a door is installed. A louvered door with equivalent

air openings for the full length of the door is acceptable.

60 sq. in.

(387.1cm²)

3”

(7.6cm)

60 sq. in.

(387.1cm²)

3”

(7.6cm)

closet door

Clearance requirements