PLAN YOUR DUCTWORK

To ensure that the blower performs to its highest

possible capacity, ductwork should be as short

and straight as possilbe.

The ductrun should not exceed 35 equivalent

feet if ducted using two separate duct runs of

the required minimum of 6" round duct or 55

equivalent feet if ducted with one single 10"

round duct (when using optional Duct Transi-

tion Kit). Calculate the length of the ductwork

by adding the equivalent feet in FIGURE 2 for

each piece of duct in the system An example

is given in FIGURE 3.

For best results, use no more than three 90°

elbows. Make sure that there is a minimum of

24" of straight duct between elbows if more

than one is used. Do not install two elbows

together. If you must elbow right away, do it

as far away from the hood's exhaust opening

as possible.

9 Feet Straight Duct

2 - 90˚ Elbows

Wall Cap
Total System

9.0 feet

10.0 feet

0.0 feet

19.0 feet

3.0 feet

5.0 feet

12.0 feet

0.0 feet

45˚ Elbow

90˚ Elbow

90˚ Flat Elbow

Wall Cap

FIGURE 1

RECIRCULATING INSTALLATIONS

IT IS HIGHLY RECOMMENDED THAT PROFESSIONAL STYLE COOKING ALWAYS BE VENTED TO THE OUTSIDE. For recirculating

installations (FIGURE 1), Charcoal Filters are necessary. Remove all three grease filters and set aside. Attach one charcoal filter to each end

of both blowers. Each charcoal filter attaches to the grid on the side of the blowers. Rotate the filter clockwise to install and counterclockwise

to remove (FIGURE 1A). Replace all three grease filters. Recirculating installations also require some duct work to divert the air out of the

top or face of the cabinet or custom hood. The duct work must not terminate inside the cabinet or custom hood.

cabinet

or

custom

hood

ceiling

duct

work

duct

work

ceiling

inca pro 38

cabinet

or

custom

hood

MAKE YOUR CUT-OUTS

1. Disconnect and move freestanding range from cabinet opening to provide easier access

to upper cabinet or custom hood. Put a thick, protective covering over cooktop, set-in range

or countertop to protect from damage or dirt.

2. Determine and clearly mark with a pencil the center line on the cabinet or custom hood

where the rangehood will be installed.

3. Determine and make all necessary cuts in the wall and/or ceiling for the ductwork. Install

the ductwork before the rangehood.

4. Determine the proper location for the Power Supply Cable. Use a 1

1/4"

Drill Bit to make

this hole. Install the cable. Use caulking to seal around the hole. DO NOT turn on the

power until installation is complete.

5. Make the cut-out opening where the rangehood will be installed (FIGURE 4).

FIGURE 4

37"

14 5/8"

CUT-OUT

FIGURE 1A

inca pro 38

FIGURE 2

FIGURE 3