RECIRCULATING INSTALLATIONS

For recirculating installations (FIGURE 1), Charcoal Filters are necessary. The

charcoal filters must be inserted behind the grease filters as indicated in (A in FIGURE

1). Recirculating installations also require some duct work to divert the air out of the

cabinet. The duct work must not terminate inside the cabinet.

MAKE YOUR CUT-OUTS

1. Disconnect and move freestanding range from cabinet opening to provide easier

access to upper cabinet and rear wall. Put a thick, protective covering over cooktop,

set-in range or countertop to protect from damage or dirt.

2. Determine and clearly mark with a pencil the center line on the cabinet where

the rangehood will be installed.

3. Determine and make all necessary cuts in the wall for the ductwork. Install the

ductwork before the rangehood.

4. Determine the proper location for the Power Supply Cable. Use a 1

1/4"

Drill Bit

to make this hole. Install the cable. Use caulking to seal around the hole. DO NOT

turn on the power until installation is complete.

5. Make the cut-out opening where the rangehood will be installed (FIGURE 2).

INSTALL THE RANGEHOOD

1. Remove the rangehood from the carton and place on a flat surface. Cover the sur-

face to prevent accidental damage. Remove all parts including the backdraft damper,

screws, field wiring box and literature package before discarding the carton.

2. Place the round damper into the exhaust opening of the rangehood and press

down.

3. Remove the bottom of the rangehood by pulling on the grey tabs (A in FIGURE

3) located on either side.

4. Fix the rangehood to the cabinet using the two spring loaded brackets, one on

each side of the rangehood (B in FIGURE 4). Using a philips screwdriver, tighten

the adjustment screw (C in FIGURE 4) until the brackets adhere tightly to the surface.

For thicknesses of LESS than

3/4",

insert a block of wood to fill in the gap between

the cabinet bottom and the spring loaded bracket.

5. IMPORTANT: Also fix the rangehood to the cabinet using the 10 screws provided

(FIGURE 4).

6. Replace the bottom of the rangehood and secure by pushing in the grey tabs (A

in FIGURE 3).

7. Remove the cover from the field wiring compartment with a phillips screwdriver.

Feed the Power Supply Cable through the electrical knockout. Connect the Power

Supply Cable to the rangehood cable. Attach the White lead of the power supply

to the White lead of the rangehood with a twist-on type wire connector. Attach the

Black lead of the power supply to the Black lead of the rangehood with a twist-on

type wire connector. Attach the Power Supply Cable grounding lead to the green screw

provided. Using the 4 holes provided screw the field wiring compartment to the wall

or cabinet as dictated by your Power Supply Cable location (screws not provided).

Replace the cover.

8. Connect the ductwork to the damper and seal all connections with duct tape.

9. Turn the power supply on. Turn on the blower and light. If the rangehood does

not operate, check that the circuit breaker is not tripped or the house fuse blown. If

the unit still does not operate, disconnect the power supply and check that the wiring

connections have been made properly.