ATTACH THE SUPPORT

4. Determine and make necessary cuts for the ductwork. The duct

opening is shown on the mounting template (L in FIGURE 7). Install

ductwork before mounting the support.

FIGURE 9

FIGURE 7

Ductless installations require

a Ductless Conversion

Kit whose components are

pictured in FIGURE 10. Do

not use the DAMPER (M

in FIGURE 1) for ductless

installations. The LOWER

CHIMNEY COVER (B

in FIGURE 1) should be

discarded and replaced by

the new one with holes from

the Ductless Conversion Kit

(D in FIGURE 10).

As indicated in FIGURE

10, place the DUCTLESS

DIVERTER (A) over the

exhaust opening of the EASY

CUBE (E). Fit the DUCTLESS

DIVERTER EXTENSIONS

HORIZONTAL (B) into the

DIVERTER (A).

FIGURE 10

FIGURE 11

MAKE THE ELECTRICAL CONNECTION

Remove the cover from the field wiring compartment. DO NOT

turn on the power until installation is complete! Connect

the Power Supply Cable to the rangehood. Connect the Green

(Green and Yellow) ground wire under the Green grounding

screw. Attach the White lead of the power supply to the White

lead of the rangehood with a twist-on type wire connector.

Attach the Black lead of the power supply to the Black lead of

the rangehood with a twist-on type wire connector.

1. Put a thick, protective

covering over cooktop,

set-in range or countertop

to protect from damage

or dirt.

2. Determine and clearly

mark with a pencil on the

ceiling where the rangehood

will be installed.

3. A template (L in FIGURE

7) for mounting the support

is supplied in the carton

with the support. Use this

template to mark holes for

support on the ceiling.

FOR DUCTLESS INSTALLATIONS

1. The UPPER CHIMNEY

COVER (C in FIGURE 11)

attaches using two screws

provided (G in FIGURE 11).

If using the High Ceiling

Chimney Kit, use the

UPPER CHIMNEY COVER

supplied with the kit. Slide

up and attach the UPPER

CHIMNEY COVER.

2. Attach the duct work to the

DAMPER (M in FIGURE 1).

Make sure to seal all joints

with duct tape to prevent

leaks.

3. The LOWER CHIMNEY

COVER (B in FIGURE 11)

attaches using two screws

provided (G in FIGURE

11). Install the LOWER

CHIMNEY COVER by

sliding it up over the support

and the UPPER CHIMNEY

COVER.

For ductless installations, line up the DUCTLESS DIVERTER

EXTENSIONS HORIZONTAL (B in FIGURE 10) with the holes

in the LOWER CHIMNEY COVER (D in FIGURE 10) and snap

in the VENT GRIDS (C in FIGURE 10).

INSTALLING THE RANGEHOOD

8. Attach the CHIMNEY SUPPORT (D in FIGURE 9) to the ceiling.

Make sure that the support is firmly attached to the ceiling. Determine

the desired length of the support structure and adjust the length of the

support by removing the four screws (indicated in FIGURE 9) with a

flat head screwdriver. Once the length of the support is determined,

install and tighten the four screws.

6. Determine the proper location for the Power Supply Cable as

indicated on the template. Use a 1 1/4" Drill Bit to make this hole. Run

the Power Supply Cable. Use caulking to seal around the hole. DO

NOT turn on the power until installation is complete! A knockout is

provided at the top of the CHIMNEY SUPPORT (D in FIGURE 9).

7. For ducted installations, place the round DAMPER (N in FIGURE

1) into the exhaust opening of the rangehood and press down.

5. If using the High Ceiling

Chimney Kit, remove

the CHIMNEY COVER

from the CHIMNEY

EXTENSION (A in

FIGURE 8). Position the

CHIMNEY EXTENSION

over the CHIMNEY

SUPPORT (B in FIGURE

8) so that the outside

edges and the electrical

holes line up. Attach the

CHIMNEY EXTENSION to

the CHIMNEY SUPPORT

using the 4 bolts (C in

FIGURE 8). Tighten bolts

securely.

FIGURE 8