Warning, Ductless – Faber Axia Isola Island Mount Canopy Rangehood Manuel d'utilisation

Page 6

Advertising
background image

Version 3/08 - Page 6

PLAN THE INSTALLATION

This rangehood can be installed as either ducted or ductless. When installed ductless, the rangehood vents out of a grate on the

back of the lower chimney. Ductless installations require a Ductless Conversion Kit, available from your dealer.
WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION, DETERMINE WHICH VENTING METHOD WILL

BE USED AND CAREFULLY CALCULATE ALL MEASUREMENTS.

The ductless Axia Isola chimney is

adjustable for varying ceiling heights as

indicated in FIGURE 5. The chimney can

be adjusted for ceilings between 7' 10 5/ 8"

and 8' 10 5/ 8" depending on the distance

between the bottom of the hood and the

cooktop (distance x in FIGURE 5).

upper

chimney

cover

ductless

lower

chimney

cover

canopy

cabinet base

x = distance from hood to cooktop

(varies depending on installation)

min - 24”, suggested max - 30”

also consult cooktop

manufacturer's recommendation

1" min

7" max

31"

36”

FIGURE 5

DUCTLESS

DIMENSIONS

x

min & max ceiling height examples

x = 30"

min

8'

4 5/8"

max

8'

10 5/8"

x = 28"

min

8'

2 5/8"

max

8'

8 5/8"

x = 26"

min

8'

5/8"

max

8'

6 5/8"

x = 24"

min

7'

10 5/8"

max

8'

4 5/8"

DUCTLESS

INSTALLATION DIMENSIONS

(not vented to the outside)

20"

2

5/8”

3

3/4”

WARNING

DUE TO THE SIZE

AND WEIGHT OF THIS

RANGEHOOD, THE

SUPPORT MUST BE

FIRMLY ATTACHED TO

THE CEILING. For plaster

or sheet rock ceilings, the

support must be attached

to the joists. If this is

not possible, a support

structure must be built

behind the plaster or sheet

rock. The manufacturer

assumes no responsibility

for injury or damage caused

by improper installations.

!