Version 09/12 - Page 5

9.0 feet

10.0 feet

0.0 feet

19.0 feet

TOOLS NEEDED FOR INSTALLATION

• Saber Saw or Jig Saw

• Drill

• 1 1/4" Wood Drill Bit

• Pliers

• Phillips Screwdriver

• Wire Stripper or Utility Knife

• Metal Snips

• Measuring Tape or Ruler

• Level

• Pencil

• Caulking Gun

• Duct Tape
PARTS SUPPLIED FOR INSTALLATION

• 1 Backdraft Damper

• 1 Vent Grate (for recirculating installations only)

• 3 front trims, white (already installed), black,

and brushed aluminum

• 1 Vinyl Trim

• 1 Literature Package
PARTS NEEDED FOR INSTALLATION

• 2 Conduit Connectors

• Power Supply Cable

• 1 Wall or Roof Cap

• All Metal Ductwork
OPTIONAL ACCESSORIES AVAILABLE

• Charcoal Filters

For non-vented installations only,

replace charcoal filters as needed

part #

FILTER1

PLAN THE DUCTWORK

The Cristal HC slideout rangehood is designed to offer wide flexibility of installations.

The rangehood can be ducted vertically or horizontally through a 6" round vent.

The unit can also be installed in a recirculating configuration. The unit comes

standard in the top venting position. FIGURES 1 and 2 show vertical and horizontal

installations for this unit. FIGURE 3 shows recirculating installation.

The Cristal HC requires 6" round ductwork. To ensure that the blower performs

to its highest possible capacity, ductwork should be as short and straight as

possilbe.

RECIRCULATING INSTALLATIONS

For recirculating installations (FIGURE 3), Charcoal Filters are necessary. Remove all four grease filters and set aside. Attach

one charcoal filter to each end of the blower. Each charcoal filter attaches to the black grid on the side of the blower. Rotate

the filter clockwise to install and counterclockwise to remove (FIGURE 3A). Replace all four grease filters. Some ductwork

must be installed to exhaust the rangehood back into the kitchen, either at the top of the cabinet or at the face of the soffit. A

plastic vent grate (FIGURE 3B) supplied with the rangehood can be used to cover the duct opening. This duct work must not

terminate into a dead air space.

FIGURE 3A

45˚ Elbow

90˚ Elbow

90˚ Flat Elbow

Wall Cap

FIGURE A

9 Feet Straight Duct

2 - 90˚ Elbows

Wall Cap
Total System

FIGURE B

3.0 feet

5.0 feet

12.0 feet

0.0 feet

VERTICAL

DUCTING

FIGURE 2

HORIZONTAL

DUCTING

FIGURE 1

For direct rear venting (FIGURE 2), you must

change the blower position. Remove the 12

screws that hold the metal housing to the

rangehood body. Remove the 4 screws that

hold the blower housing to the metal housing.

Rotate the blower 90 degrees toward the back

and then flip it over 180 degrees. Be sure that

the power supply cable is properly positioned.

Replace all screws, making sure that they are

firmly fastened.

cabinet

ceiling

6” round

duct

hood

cabinet

ceiling

6” round

duct

hood

soffit

vent grate

vent grate

FIGURE 3B

FIGURE 3

For satisfactory performance the duct run should

not exceed 50 equivalent feet if ducted using the

required minimum 6" round duct. The equivalent

feet in FIGURE A for each piece of duct in the

system An example is given in FIGURE B. For

best results, use no more than three 90°

elbows. Make sure that there is a minimum of

24" of straight duct between elbows if more

than one is used. Do not install two elbows

together. If you must elbow right away, do it

as far away from the hood's exhaust opening

as possible.