Powering up and setting the temperature – Honeywell AQ1000TP2 Manuel d'utilisation

Page 6

Advertising
background image

3

69-2245EF

Powering up

The thermostat is powered through the AQ2000 hydronic control panel. It turns on when the zoning module is
energized.
At power-up, the message

ALL

ZONES

SCHEDULE

will flash for the first 15 seconds if the thermostat has been

configured for ALL-ZONES scheduling (see page 19). In this case, at first power-up, the thermostat will adopt
the schedule settings from the AQ2000 hydronic control panel*. All thermostats configured for ALL-ZONES
scheduling should have therefore the same schedule settings.
* If the AQ2000 controller does not support ALL-ZONES scheduling (manufactured prior to V2 software
build), at first power-up the thermostat will initially retain its schedule settings. However, as soon as any
modification is made to any of the thermostats configured for ALL-ZONES scheduling, all the other thermostats
will adopt the schedule of that thermostat.

Setting the Temperature manually

The thermostat displays the actual (measured) temperature of the zone.

To display the setpoint temperature, press the

or

button once. The setpoint will be displayed for

the next 5 seconds.

SET

HEAT

or

SET

COOL

appears at the same time as the setpoint to indicate the

thermostat is maintaining the temperature at the heating setpoint or cooling setpoint respectively.

To change the setpoint, press the

or

button until the desired temperature is displayed. To scroll

faster, press and hold the button.

NOTE: If the hydronic control panel has locked the thermostat’s keypad,

appears on the screen. This

means the thermostat settings cannot be changed.

Powering up and setting the temperature

400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 3 Wednesday, June 18, 2008 2:32 PM

Advertising