OPERATING INSTRUCTIONS

62.9679.01_UL

Seite 11

8.

MALFUNCTION

Fryer does not heat up.

• The STB limiter has

tripped.

• Defective thermostat.

• The oil temperature

has exceeded 445°F
(230°C).

• The capillary tube sen-

sor is damaged.

• The heating is opera-

ting in the trough wit-
hout oil.

• Oil level is too low.

- Contact the nearest

service station by tele-
phone.

- Inform After-sales ser-

vice.

- Inform After-sales ser-

vice.

- Inform After-sales ser-

vice.

- Pour in oil.

-
- Top up with oil.

Fryer overheats; the oil
smokes.

• Oil level too low.

- Fill with oil up to the

max. mark.

Flame smokes.

• Gas mix too rich.
• Partially blocked burner

gaps.

- Inform Customer Ser-

vice.

Long yellow flame tips.

• Mixing tube narrowed by

dirt.

- Inform Customer Ser-

vice.

Flame lifts off.

• Exit velocity too high due

to blocked burner gaps.

• Pressure regulator on

gas cylinder not opera-
ting correctly.

- Inform Customer Ser-

vice.

Flame flashes back.

• Mixture too lean.
• Insufficient exit velocityat

burner gaps.

• Soiled airways
• Blocked nozzle.

- Inform Customer Ser-

vice.

No flame or flame too
small.

• Blocked nozzle or mixer

tube.

• Blocked gas tap.
• No gas.
• Insufficient gas pres-

sure.

- Inform Customer Ser-

vice.

- Check gas tap setting.

No flame at low setting.

• Blocked low setting

nozzle.

- Inform Customer Ser-

vice.

No flame.

• Blocked burner gaps.
• Blocked nozzle.

- Clean pilot burner cap.

Flame goes out after con-
trol valve release.

• Thermo-element insuf-

ficiently heated (dirty?)

• Defective thermo-ele-

ment

- Inform Customer Ser-

vice.

Flame too small or too
large.

• Primary air ratio adju-

sted.

• Nozzle blocked.

- Inform Customer Ser-

vice.

Malfunction

Possible cause

Remedy

Pilot burner