3.1

GAS BURNER

So far as is necessary, the pilot burner and main burner are
cleaned by after-sales service.

3.2

FLAME

In a visual check, the flames must be dark blue without any
upper yellow or orange tips; they must be stable and soot-free
and adhere firmly to the outlets.
If there is a lack of primary air, the flame has yellow streaks
and tips; if there is too much primary air, the flame is short,
transparent and tends to lift off the burner.
When the flame is correctly adjusted, it must not lift off or back-
fire when the burner is cold as well as warm.
The flame will backfire into the inside of the burner when the
speed of the gas-air mixture through the burner outlets is too
low, particularly when the air passages are dirty.
The different ignition processes must also take place without
any delays. This concerns: ignition, arc-through and. extending
the flame over the whole burner area.
If the flame fails to meet all the requirements, cleaning or
maintenance is necessary.

4.

MALFUNCTION

The burners are not accessible to operating personnel.
Therefore, in the case of a fault, specialist staff must be reque-
sted.

5.

STORAGE SPACE

The storage space (Fig.10) is incorporated into the base unit.
Recommended accessories:

- Shelf holder (1) 2 off.

- Shelves (2) 1 off.

Malfunction

Possible cause

Remedy

Flame smokes.

• Gas mix too rich.
• Partially blocked burner

gaps.

- Inform Customer Ser-

vice.

Long yellow flame tips.

• Mixing tube narrowed by

dirt.

- Inform Customer Ser-

vice.

Flame lifts off.

• Exit velocity too high due

to blocked burner gaps.

• Deformed burner cover.
• Pressure regulator on

gas cylinder not opera-
ting correctly.

- Inform Customer Ser-

vice.

Flame flashes back.

• Mixture too lean.
• Insufficient exit velocity

at burner gaps.

• Soiled airways
• Blocked nozzle.
• Deformed or burnt-out

burner cover

- Inform Customer Ser-

vice.

No flame or flame too
small.

• Blocked nozzle or mixer

tube.

• Blocked gas tap.
• No gas.
• Insufficient gas pres-

sure.

- Inform Customer Ser-

vice.

- Check gas tap setting.

No flame at low setting.

• Blocked low setting

nozzle.

- Inform Customer Ser-

vice.

Pilot burner

No flame.

• Blocked burner gaps.
• Blocked nozzle.

- Clean pilot burner cap.

Flame goes out after con-
trol valve release.

• Thermo-element insuf-

ficiently heated (dirty?)

• Defective thermo-ele-

ment

- Inform Customer Ser-

vice.

Flame too small or too
large.

• Primary air ratio adju-

sted.

• Nozzle blocked.

- Inform Customer Ser-

vice.

1

Shelf holder

2

Shelves

Fig.10 Storage space