Venting installation – Desa (V)B36I Manuel d'utilisation

Page 7

Advertising
background image

www.desatech.com

109034-01G

7

Figure 8 - Lineal Gain

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

36"

Fireplace

37

1

/



"

12-8DM

1-8HT

Pipe Section

10

5

/

8

"

18-8DM

18-8HT

Pipe Section

16

5

/

8

"

24-8DM

4-8HT

Pipe Section

3

5

/

8

"

36-8DM

36-8HT

Pipe Section

34

5

/

8

"

48-8DM

48-8HT

Pipe Section

46

5

/

8

"

RT-8DM

RT-8HT

Round Termination

6

7

/

8

"*

RTL-8DM

RTL-8HT

Round Termination

7

3

/

4

"*

RTT-8DM

RTT-8HT

Round Termination

with Slip Section

6

7

/

8

" to

3

1

/

8

"*

RTTL-8DM

RTTL-8HT

Round Termination

with Slip Section

8

1

/



" to

1

1

/



"*

ET-8DM

ET-8HT

Square Chase-Top

12"*

ETO-8DM

Square Chase-Top

with Mesh

12"*

ETL-8DM

ETL-8HT

Square Chase-Top

with Slip Section

7" to 15"*

ETLO-8DM

Square Chase-Top

with Mesh & Slip

Section

12" to

5

1

/



"*

* The lineal gain for the terminations is mea-
sured to the flue gas outlet height.

Hemmed
End

8" Stainless
Inner Pipe

1

3

/

8

"

Galvanized
Outer Pipe

Figure 7 - Outside Air Kit

Secure to Collars with Metal Tape, Screws
or Straps (Min. of 1/4" x 20" in size)

Air Inlet
Location
Must Allow
For Bushes
or Snow

Vent Hood
Required for
Wall Installation

Air Inlet
Eyebrow

Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)

VenTing inSTallaTion

OPTIONAL OUTSIDE AIR KIT
(MODEL AK4/AK4F)

Installation of outside air kit should be per-
formed during rough framing of fireplace due
to the nature of it's location. Outside combus-
tion air is accessed through a vented crawl
space (AK4F) or through a sidewall (AK4).
See Figure 24 on page 15 for instruction of
operating air kit.

CAUTION: Combustion air

inlet ducts shall not terminate

in attic space.

The maximum height for the

air vent can not exceed 3 feet

below the flue gas outlet of the

termination.

CHIMNEY PIPE

DESA Heating, LLC chimney system con-
sists of 12", 18", 24", 36" and 48" snap-lock,
double-wall pipe segments, planned for
maximum adaptability to individual site re-
quirements. Actual lengths gained after fitting
overlaps must be taken into consideration
(lineal gain) and are given in lineal gain chart
(see Figure 8).
Lineal gain is actual measurable length of a
part after two or more parts are connected.

WARNING: The opening in

collar around chimney at top of

fireplace must not be obstructed.

Never use blown insulation to fill

chimney enclosure.