Advance planning and installation options, Installation preparation, Advance planning – GE ZGU384L Manuel d'utilisation

Page 5: Installation options

Advertising
background image

ADVANCE PLANNING

• Refer to “Installation Preparation” for

information on appropriate placement and
necessary clearances when planning
installation.

• Avoid placing cabinetry directly above cooktop

when possible.

• If cabinetry is used above cooking surface:

– Use cabinets no more than 13

deep.

– Maintain 30

minimum clearance between

cooktop and unprotected cabinets directly
above cooktop.

– If clearance is less than 30

, protect cabinet

bottoms with flame-retardant millboard at
least 1/4

thick, or gypsum board at least

3/16

thick, covered with 28 gauge sheet

steel or .02

thick copper.

– Clearance between cooktop and protected

cabinetry must not be less than 24

.

– An exhaust hood that projects at least 5

beyond front of cabinets can reduce risk
of burns caused by reaching over heated
surface units.

– Working areas adjacent to the cooktop

should have 18

minimum clearance between

countertop and cabinet bottom.

• A 30

or wider exhaust hood with 350 CFM or

greater airflow rating is recommended for use
over this Monogram cooktop.

• Installation must conform with local codes.

In the absence of local codes, the gas cooktop
must comply with the National Fuel Gas Code,
ANSI Z223.1, latest edition.

• Gas supply should be located near the opening

for this cooktop (see Preparing the Opening and
Gas Connection sections of this manual). The
supply should provide natural gas at 7

of water

column pressure (11

of water column for LP

gas) and a maximum of 14

of water column

for natural or LP gas.

• The electric spark ignition feature for this

model requires a 120V electrical power supply
be located in the immediate vicinity of this
cooktop (see Electrical Connections section
of this manual).

WB28T10185 High Altitude Kit
For operation above 5,000 feet, order
WB28T10185 Conversion Kit. This kit includes
orifices for both LP and Natural gas operation.

Installation Preparation

5

INSTALLATION OPTIONS

Cooktop and ZVB30 Downdraft Vent Combination
Installation

These cooktops may be installed with a 30

Monogram Downdraft Vent, model ZVB30.
See page 12 for cutout and clearances.

– The countertop must have a deep flat surface to

accommodate the combined installation of the
cooktop and vent.

– The downdraft vent with blower, motor and

ductwork will occupy the base cabinet.

– Consideration must be given to electrical and gas

supply locations. See page 8.

Cooktop and ZTD910 or ZKD910 Warming Drawer
Combination Installation

These cooktops may be installed over a Monogram
30

or 27

Warming Drawer, model ZTD910 or

ZKD910. See page 13 for cutout and clearances.

– Consideration must be given to electrical and gas

supply locations. See page 8.

Cooktop and ZET1, ZEK938 or ZET938 Single Oven
Combination Installation

These cooktops may be installed over a Monogram
27

or 30

Oven, model ZET1, ZEK938 or ZET938.

See page 14 for cutout and clearances.

– Consideration must be given to electrical and gas

supply locations. See page 8.

Installation Above Cabinet Drawers

• When installing the cooktop above a base

cabinet with drawers, it may be necessary to
use a shorter depth (front to back) drawer to
allow clearance for the gas connection.

Advertising