Tools you will need, Adjusting the regulator, Changing the orifices – GE ZGU384L Manuel d'utilisation

Page 15: Installation, Instructions, Caution, Warning, Convert natural gas model zgu384nsmss, Adjust the regulator, 1change burner orifices

Advertising
background image

15

ADJUST THE REGULATOR

A. Disconnect all electrical power, at the main circuit

breaker or fuse box.

B. Shut off the gas supply to the cooktop by closing the

manual shut-off valve.

C. Adjust the pressure regulator by the following

instructions:
• Unscrew the cap.
• Place your thumb against the flat side of the spring

retainer and press down to remove the retainer.

• Carefully look at the spring retainer to locate the NAT

or LP position.

• Turn the spring retainer over so that the desired gas is

showing on the bottom.

• Snap the retainer back into position.
• Screw the cap back onto the regulator.

1

CHANGE BURNER ORIFICES

INSTALLATION TIP: First remove all
orifices and then start replacing them.
This will help to prevent the possibility
that some may not be replaced.
A. Remove the burner grates,

burner caps and burner heads.

B. Using a 7mm nut driver, remove the

top burner orifices. There are two
orifices per burner.
The main orifice is
located low in the center
of the burner, while the
simmer orifice is located
higher beside the center
of the burner.

2

DOWN

FOR OFF

NAT

LP

LP

NAT

LP

NAT

NAT

LP

Gasket

Cap

Spring
retainer

L.P./propane
position

NAT.

position

Pressure regulator

Burner cap

Burner

head

Burner

base

Spark igniter

Main
orifice

Simmer
orifice

SAFETY INFORMATION

The pressure regulator and burner orifices are set for
natural gas operation.

To convert this cooktop from natural gas operation to
LP operation, the regulator and burner orifices must be
converted. LP burner orifices are attached to the regulator.

CAUTION

— The cooktop, as shipped from

the factory, is set for use with its intended gas. If you
wish to use your cooktop with the alternate gas, you
must first replace the orifices and convert the pressure
regulator.

WARNING

— This conversion must be

performed by a qualified installer or gas supplier in
accordance with the manufacturer’s instructions and
all codes and requirements of the authority having
jurisdiction. Failure to follow instructions could result in
serious injury or property damage. The qualified agency
performing this work assumes responsibility for the
conversion.

CAUTION

— The following adjustments

must be made before turning on the burner. Failure
to do so could result in serious injury. Be sure pressure
regulator has been converted as described in Step 1.

TOOLS YOU WILL NEED FOR
CONVERSION

Safety glasses

Small flat-head

screwdriver

(2 to 2.4 mm or

3/32

tip size,

60 mm long)

Crescent wrench

7mm nutdriver

Installation

Convert Natural Gas Model ZGU384NSMSS

Instructions

to LP Gas Operation

If sold outside the U.S. and Canada:

WARNING:

If you wish to use this product

with Liquefied Petroleum (LP) gas containing greater
than 10% butane, you must purchase the butane
conversion kit #WB28T10238. To order, please call
1.888.664.8403 or 1.787.276.4051.

Advertising