HE225A,B AND HE265A,B BY-PASS FLOW-THROUGH HUMIDIFIERS WITH AGION

3

69-1423EF—04

The HumidCalc+™ software inside your automatic humidity control is designed to

measure or infer outdoor temperature and automatically adjust the humidity based on

the frost factor setting that the homeowner sets to allow for variances in furnace size,

window type and insulation.

The Automatic Humidity Control with HumidiCalc+™ requires an initial adjustment

period. For maximum humidification, set the H1008 to 10 and run the fan continuously.

Check for condensation on windows after a cold night. If there is no condensation,

leave the setting at 10. If there is condensation, lower the frost factor dial one setting.

Continue to check for condensation on cold mornings until the correct humidity setting

is reached for your home. Allow two days between adjustments to determine if further

adjustment is necessary. Once you have tuned in the proper setting, you should never

have to adjust it again. HumidiCalc+™ takes over and makes any future adjustments

caused by varying outdoor temperatures, thus reducing moisture build-up on windows

while maintaining the optimal humidity level.

HOW YOUR HUMIDIFIER WORKS

Your Enviracaire Elite™ humidifier uses the principle that vapor (evaporated water) is

created when warm air blows over a water soaked area. As the vapor circulates, the

relative humidity rises.

Your humidity control monitors the relative humidity and activates the humidifier

accordingly. The humidifier has a water supply that dispenses water evenly over the

AgION™ antimicrobial humidifier pad. The warm dry air, from the furnace, passes over

the humidifier pad and picks up the moist air to circulate it throughout your home.

Humidified air feels warmer and more comfortable so you may be able to lower your

thermostat heating setpoint, which saves money on your heating fuel bills. The end

result is that your humidifier gives you a cleaner, more comfortable environment that is

also energy efficient.

MAINTAINING YOUR HUMIDIFIER

A regular maintenance program prolongs the life of your humidifier and provides a

more comfortable home. Frequency of cleaning depends on the condition of your

water. You can use either hard or soft water in your humidifier, but hard water mineral

deposits are more difficult to clean than soft water deposits. For optimum performance,

Honeywell recommends replacing the AgION™ antimicrobial pad once a year. Use the

following procedure to clean your Honeywell humidifier.

Humidity Level

Recommended Setting

Insufficient humidity

Increase the frost factor dial by one setting.

Condensation on windows

Decrease the frost factor dial by one setting.