HE225A,B AND HE265A,B BY-PASS FLOW-THROUGH HUMIDIFIERS WITH AGION

69-1423EF—04

2

OPERATING YOUR HUMIDIFIER

HE225A,HE265A

Your Enviracaire Elite™ HE225A and HE265A

Humidifiers from Honeywell are controlled by the

H8908B Convertible Humidity Control. The

convertible humidity control is installed either on an

interior wall in the living area, or on the return air duct.

Choose the humidity control setting using the

combination relative humidity/outdoor temperature

setting scale on your humidity control dial. Match the

dial setting to the outdoor temperature for optimizing

the humidity level while reducing moisture

condensation on your windows. The table below can

also be used to adjust humidity control to the

recommended setting.

NOTE: As outside temperature drops, the recommended humidity control setting is

lowered to adjust for effects of dewpoint. These settings should reduce accu-

mulation of moisture and ice on your windows and other areas of your home.

Some indoor activities such as cooking, showering and clothes drying can cause

excessive levels of humidity and start the accumulation of moisture on your windows.

NOTE: If this condition persists for more than a few hours, set the humidity control to

the lowest setting to turn off the humidifier. If the condition does not improve,

ventilate your home to remove the moisture.

HE225B,HE265B

Your Enviracaire Elite™ HE225B and HE265B

Humidifiers are controlled by the Honeywell H1008

Automatic Humidity Control with HumidiCalc+™. The

automatic humidity control is mounted in the return air

duct where it can be exposed to the air stream of the

return air.

At Outside

Temperature

Recommended

Control Setting

At Outside

Temperature

Recommended

Control Setting

-20°F (-29°C)

15

+10°F (-12°C)

30

-10°F (-23°C)

20

+20°F (-7°C)

35

0°F (-18°C)

25

Above 20°F (-7°C)

40

Humidity Control

Régulateur d'humidité

-20

°F

-10

°F

0

°F

+10

°F

+20

°F

Over 20 °F

15%

20%

25%

30%

35%

40%

HUMIDITY

SETTING

OUTDOOR

TEMPERATURE

-30

°C

-25

°C

-20

°C

-10

°C

-5

°C

Over 0

°C

M14694

M12817

H1008A