1) Assemble mounting screws to backpan using hexnut.
2) At the center of the backpan are knockout slots. Remove

the set that matches your outlet box.

3) Secure the backpan to the outlet box.
4) TURN OFF POWER.

MPORTANT: Before you start, NEVER attempt any work

without shutting off the electricity until the work is done.

a) Go to the main fuse, or circuit breaker, box in your

home. Place the main power switch in the “OFF”

position.

b) Unscrew the fuse(s), or switch “OFF” the circuit breaker

switch(s), that control the power to the fixture or room

that you are working on.

c) Place the wall switch in the “OFF” position. If the fixture

to be replaced has a switch or pull chain, place those in

the “OFF” position.

5) Connect fixture ground wire to outlet box ground wire with

wire connector. Never connect ground wire to black or white

power supply wire.

6) Make wire connections (connectors not provided). Reference

chart below for correct connections and wire accordingly.

7) Carefully push wire connections back into outlet box making

sure all connections remain secure.

8) Slip faceplate over backpan. NOTE: Be certain wires do not

get pinched between backpan and faceplate.

9) Thread screws into holes in side of faceplate and into backpan.

Tighten screws to secure fixture in place.

10) Bulbs are accessible through front glass panel. To open

glass panel, raise latch up.

INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/
OR IN WET LOCATIONS.
11) Mounting surface should be clean, dry, flat and 1/4” larger

that the canopy on all sides. Any gaps between the mounting

surface and canopy exceeding 3/16” should be corrected as

required.
12) With silicone caulking compound, caulk completely around

where back of canopy meets the wall surface to prevent

water from seeping into outlet box.

1) Installer les vis de montage sur le panneau arrière à l’aide de

l’écrou hexagonal.

2) Au centre du panneau arrière se trouvent des fentes amovibles.

Enlever l’ensemble correspondant à votre boîte à prises.

3) Visser le panneau arrière sur la boîte à prises.
4) COUPER LE COURANT ÉLECTRIQUE.

IMPORTANT: TOUJOURS couper l’électricité avant de

commencer le travail.

a) Localiser le coffret à fusibles ou le disjoncteur du

domicile. Mettre l’interrupteur principal en position d’Arrêt.

b) Dévisser le ou les fusibles (ou mettre le disjoncteur sur

Arrêt) qui contrôlent l’alimentation vers le luminaire ou la

pièce dans laquelle le travail est effectué.

c) Mettre l’interrupteur mural en position d’Arrêt. Si le

luminaire à remplacer est doté d’un interrupteur ou

d’une chaîne connectée à l‘interrupteur, placer ces

éléments en position d’Arrêt.

5) Avec l’attache-fil, connecter le fil de mise á la terre au fil

d’alimentation noir ou á celui qui est blanc.

Connect Black or

Red Supply Wire to:

Connect

White Supply Wire to:

Black

White

*Parallel cord (round & smooth)

*Parallel cord (square & ridged)

Clear, Brown, Gold or Black

without tracer

Clear, Brown, Gold or Black

with tracer

Insulated wire (other than green)

with copper conductor

Insulated wire (other than green)

with silver conductor

*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)

Neutral Wire

Date Issued: 10/4/13

IS-49154-CB

BACKPAN

PANNEAU ARRIÈRE

FIXTURE/FACEPLATE

LUMINAIRE/ PLAQUE DE CONTACT

SCREW

VIS

INSTRUCTIONS

For Assembling and Installing Fixtures in Canada

Pour L’assemblage et L’installation Au Canada

6) Connecter les fils (connecteurs non fournis). Se reporter au

tableau ci-dessous pour faire les connexions.

7) Replacer soigneusement les fils dans la boîte à prises en

veillant à ce que les connexions ne soient pas déconnectées.

8) Passer la plaque de contact sur les vis de montage et le

panneau arrière. REMARQUE: Veiller à ce que les fils ne se

retrouvent pas coincés entre le panneau arrière et la plaque

frontale.
9) Serrer les vis sur les trous situés au-dessus de la plaque de

contact. Serrer les vis pour fixer le luminaire.

10) Les ampoules sont accessibles via le panneau de verre

avant. Pour ouvrir le panneau de verre, soulever verrou vers

le haut.

INSTRUCTIONS DE MONTAGE DE LUMINAIRE À L’EXTÉRIEUR
ET/OU DANS DES LIEUX HUMIDES.
11) La surface de montage doit être propre, sèche, plate et de

0,6 cm plus épaisse que le cache sur tous les côtés. Tout

écart entre la surface de montage et le cache dépassant de

0,5 cm doit être rectifié selon les besoins.

12) À l’aide de matériaux d’étanchéité à la silicone, calfeutrer

bien autour où l’arrière du cache entre en contact avec le

mur pour empêcher l’eau de passer dans la boîte de

raccordement.

We’re here to help

866-558-5706

Hrs: M-F 9am to 5pm EST

FIXTURE

LUMINAIRE

Connecter le fil noir ou

rouge de la boite

Connecter le fil blanc de la boîte

A Noir

A Blanc

*Au cordon parallèle (rond et lisse)

*Au cordon parallele (à angles droits el strié)

Au bransparent, doré, marron, ou

noir sans fil distinctif

Au transparent, doré, marron, ou

noir avec un til distinctif

Fil isolé (sauf fil vert) avec

conducteur en cuivre

Fil isolé (sauf fil vert) avec

conducteur en argent

*Remarque: Avec emploi d’un fil paralléle
(SPT I et SPT II). Le fil neutre est á angles
droits ou strié et l’autre fil doit étre rond ou
lisse (Voir le schéma).

Fil Neutre

FRONT GLASS PANEL

PANNEAU DE VERRE AVANT

LATCH

VERROU

Advertising