VENTILATION

WARNING: Provide a fresh air

opening of at least three square

feet (2,800 square cm) for each

100,000 Btu/Hr rating. Provide

extra fresh air if more heaters

are being used. The minimum

ventilation requirements must

be followed to avoid risks as-

sociated with carbon monoxide

poisoning. Make certain these

requirements are met prior to

operating heater.

Example:

A 165 model heater requires one of

the following:
• a two-car garage door (16 ft. [4.88 m] wide

opening) raised four inches (10.16 cm)

• a single-car garage door (9 ft. [2.74 m] wide

opening) raised seven inches (17.78 cm)

• two, thirty-inch (76.20 cm) windows raised

twelve inches (30.48 cm)

OPERATION

IMPORTANT: Review and under-

stand the warnings in the Safety

Information section, page 2.

They are needed to safely oper-

ate this heater. Follow all local

ordinances and codes when

using this heater.

TO START HEATER

1. Follow all ventilation and safety informa-

tion.

2. Fill fuel tank with kerosene, #1/#2 diesel/fuel

oil, JET A or JP-8 fuels.

3. Attach fuel cap.
4. For thermostat models 55T, 70T, 115T, and

165T, turn thermostat knob clockwise to the

high position.

5. Plug heaterʼs power cord into approved,

grounded, three-wire extension cord. Extension

cord must be at least six feet (1.8 meters) long.

Extension Cord Size Requirement

6 to 10 feet (1.8 to 3 meters) long, use 18 AWG

(0.75 mm2) rated cord

11 to 100 feet (3.3 to 30.5 meters) long, use

16 AWG (1.0 mm2) rated cord

101 to 200 feet (30.8 to 61 meters) long, use

14 AWG (1.5 mm2) rated cord

6. Plug extension cord into standard 120 volt/60

hertz, 3-prong grounded outlet. Note: Ignitor will

preheat for five seconds, then heater will start.

7. For thermostat models 55T, 70T, 115T, and

165T, adjust thermostat knob to the desired

setting. Note: A cold heater may affect

the thermostat setting. This thermostat is a

general-heating control. It is not intended for

precise temperature control. Adjust thermostat

until heater cycles at the desired setting.

TO STOP HEATER

Unplug extension cord from outlet.

TO RESTART HEATER

1. Unplug extension cord from outlet and wait

10 seconds. (Wait two minutes if heater has

been running.)

2. Repeat steps under To Start Heater.