2

SAFETY INFORMATION

IMPORTANT: Read this owner’s

manual carefully and completely

before trying to assemble, op-

erate, or service this heater.

Improper use of this heater can

cause serious injury or death

from burns, fire, explosion,

electrical shock, and carbon

monoxide poisoning.

DANGER: Carbon monoxide

poisoning may lead to death!

Early signs of carbon monoxide poisoning re-

semble the flu, with headaches, dizziness, and/or

nausea. If you have these signs, the heater may not

be working properly. Get fresh air at once! Have

heater serviced. Some people (such as pregnant

women, persons with heart or lung disease, persons

with anemia, those under the influence of alcohol,

and those at high altitudes) are more affected by

carbon monoxide than others.
1. Use only kerosene, #1/#2 diesel/fuel oil, JET A

or JP-8 fuels to avoid risk of fire or explosion.

Never use gasoline, naphtha, paint thinners,

alcohol, or other highly flammable fuels.

2. Use only with the electrical voltage and fre-

quency specified on model plate.

3. Heater must be grounded. Use only a properly

grounded three-wire extension cord. Plug into

grounded outlet only.

4. Use only in areas free of flammable vapors or

high dust content.

5. Minimum clearance from any combustible

materials: 8 feet (244 cm) from hot air outlet;

6 feet (183 cm) from top; and 2 feet (61 cm)

from sides and inlet.

6. Locate heater on a stable and level surface

while hot or operating or a fire may occur.

7. Use only in well ventilated areas. Provide venti-

lation of at least three square feet (2,800 square

cm) for each 100,000 Btu/Hr of rating.

8. Keep children and animals away from heater

at all times.

9. Never start heater when combustion chamber

is hot or if fuel has accumulated in combus-

tion chamber.

10. When used with a thermostat, heater may start

at anytime.

11. When heater is moved or stored, it must be in

a level position or fuel spillage may occur.

12. Use heater only in accordance with local

ordinances and codes.

13. Never use gasoline, crankcase drainings,

naphtha, paint thinners, alcohol, or other

highly flammable fuels.

14. Never use heater where gasoline, paint thin-

ner, or other highly flammable vapors are

present.

15. Never use heater in living or sleeping areas.
16. Never leave a heater plugged in without adult

supervision if children or animals are likely to

be present.

17. Never move, handle, refuel, or service a hot,

operating, or plugged-in heater.

18. Never block air inlet at motor end (rear) of

heater.

19. Never attach duct work to front of heater.
20. Never attach heater to external fuel tank.

UNPACKING

1. Remove all protective packaging that has been

applied to heater for shipment

2. Remove heater from carton.
3. Check heater for any shipping damage. If dam-

age is found, promptly inform dealer where

heater was purchased.

Advertising