Drain, Requirements, Drain connection – Whirlpool 810 Manuel d'utilisation

Page 6: Recommended methods, Drain requirements

Attention! Le texte de ce document a été détectée automatiquement. Pour consulter le document original, vous pouvez utiliser le mode "Original".

Advertising
background image

Drain

requirements

The drain hose must connect to the

house plumbing at a minimum of
20 Inches (50.8 cm) above the
floor. This will prevent backflow or
water siphoning out of dishwasher
during operation.

If the drain hose Is routed to a

connection point less than 20

Inches (50.8 cm) above the floor,

the drain hose must form a loop

20 Inches (50.8 cm) above the

floor. An air gap must be used In

the high drain loop.

Do Not kink drain hose and copper
tubing.
Do Not use drain hose or fittings

that are less than 1/2 Inches

(1.3 cm) I.D.

The drain hose

should be 1 /2"

(1

.3 cm) minimum

I.D.

g

20" (50.8 cm)

flexible hose and no |

min. to floor

longer than 20 feet ® y
(6 m). Flexible hose must be
resistant to heat and detergent.
Flexible hose is available through
your local plumbing, hardware
and automotive supply stores.

If connection to an air gap Is

required, an air gap kit (Part No.
300096) is available from your local

parts dealer. If another brand air

gap is used, it should be checked
to make sure it allows for the same

water flow.

Install air gap according to kit

instructions.

If connecting to a disposer,
remove disposer knockout or plug
before connecting drain line.

Connect the air gap to a waste
tee or disposer using a rubber
connector. Most disposers have

7/8" connectors, or special

connectors are available from

local plumbing supply sources.

Drain connection

1 ■ Cuta 1-1/2" (3.8 cm) hole in

cabinet wall for the drain hose.

Important:
Remove the disposer knockout

plug before connecting the drain
hose.

Cut hos© connector to fit if needed.

-drain hose

drain hose connector

I Attach drain to an air gap,

waste tee or waste disposer. See

"Recommended methods," and

"Alternate methods."

If connecting drain hose to an air
gap or waste tee, cut end of drain
hose as shown. Do Not cut drain
hose when connecting to a 7/8"
disposer connector. Do Not cut

ribbed section to shorten drain
hose.
Secure drain hose with screw- or
spring-type clamp provided.

3

b

Rough in drain line to cabinet

opening through 1-1/2" (3.8 cm)
hole in cabinet wall.

Recommended methods:

Drain ho$e to air gap

air-gap kit

(Part No.

300096)

spring

type

clamp

20" (50.8 cm)

minimum

clearance

to floor

screw-

or

spring­

type

clamps

Entry must be

above trap.

^Cut hose

connector

to fit.

Drain hose to air gap to

air-gap kit

(Part No.

300096)

Lr

.spring­

type

clamp

Cut hose

connector

or to fit.

2

Q„

sEntrymustbe

. (50.8 cm)

above trap,

minimum

clearance

to floor

Install air gap according to kit
instructions. If other brands of

air gaps are used, they should

be checked to make sure they
allow for the same air flow.

Connect the air gap to a
waste tee or disposer using a

rubber connector.
Most disposers have 7/8"
connectors or special
connectors are available at
plumbing supply houses.

Knock out disposer Inlet plug

from Inlet. If Inlet plug falls

Inside disposer,

you must

remove Inlet

plug before

connecting
drain hose. If

disposer Is
already Installed In
sink, you may need to take out

disposer to remove Inlet plug.

disposer

Inlet plug

Page 6

Advertising
Ce manuel est liée aux produits suivants:

890, 806, 801