• Alarm IN/OUT (ALARM IN/OUT)

Move the cursor to ALARM IN/OUT, then press the CAM (SET) key.

ALARM I/O submenu appears.

Note: While the camera is in AF mode or the lens moves between

WIDE and TELE, alarm input may be ignored if several alarm

inputs are received in succession.

ALARM IN 1-4

Alarm input signals are supplied from external devices through

the ALARM IN connector to turn the camera to a preset position.

1. Move the cursor to ALARM IN 1* and select a preset position or

OFF by moving the joystick, then press the CAM (SET) key.

* Set ALARM IN 2, 3 and 4 in the same way as ALARM IN 1.

SPECIAL 1 menu

** SPECIAL 1 *•

PRIVACY ZONE

OFF(ENB)4

PROPO.P/T

ON

AREA TITLE

ON (USER)-«

PATROL

STOP

’ALARM IN/ODT

t

PASSWORD LOCR

OFF'«

CLEANING

OFF

EL-ZOOM

ON

PRESET ALH

OFF

IMAGE HOLD

OFF

RET

ALARM I/O submenu

•• ALARM IH/OOT *•

ALARM IN 1

OFF

ALARM IN 2

OFF

ALARM IN 3

OFF

ALARM IN 4

OFF

CNT-CLS 1

OFF

TIME ODT

LOOMS

CNT-CLS 2

OFF

COAX А1Л OUT

OFF

1 POSI, 2 POSI, 3 POSI, 4 POSI: Preset position. If an alarm input is received, the camera turns to a

preset position, then sends alarm output signal. Position number correspond to alarm input num­

bers (1 -1,2-2, 3-3 and 4-4),

B/W: Available for ALARM INPUT 4 only. The camera changes its mode from color to black and white

if ALARM IN 4 is supplied.

OFF: The camera ignores alarm inputs.

Note: If two or more alarm inputs are received while the camera is moving to a preset position, the

camera starts to aim at preset positions in small preset numerical order after current positioning.

CNT-CLS 1-2 (Output)

Two contact closure signals (Open collector type) are output through the ALARM OUT connector.

1. Move the cursor to CNT-CLS 1, then select OFF, ALARM or AUX 1 by moving the joystick to the right

or left.

When ALARM is selected, TIME OUT appears. Select an appropriate duration from among 100 MS,

200 MS, 1000 MS (1 s), 2000 MS (2 s), 4000 MS (4 s) by moving the joystick to the right or left.

Note: The shorter the duration, the more frequent will be the detection output.

2. Move the cursor to CNT-CLS 2, then select OFF, B/W or AUX 2 by moving the joystick to the right or

left.

OFF: Contact closure signals are inactivated.
ALM: Available for CNT-CLS 1 only. Motion detection is output,

AUX 1(2): An alarm signal is output when the camera receives a command from the controller.

B/W: Available for CNT-CLS 2 only, ON (active) is output when the camera operates in black and

white mode if ALARM IN 4 is set to B/W.

Note: We recommend that you set the connected external device to ignore the shorter alarm outputs

of 90 ms or less from the camera.

COAXIAL ALARM OUT

Alarm output signals are supplied through the coaxial cable.

1. Move the cursor to COAX and select ON or OFF.

31