APPENDIX

This appendix details the elements for communication between the Monitor and the System Controller. For the communication

parameter settings, refer to the SETUP PROCEDURES on page 8.

■ Communication Protocol

• Data Format

The controller sends messages to operate the monitor in the format shown below.

Code

ASCII

[STX] [ADuuu] <Unit Address> [;] <Command> [;] <Parameter> [EXT]

(02H) (

) ( ) (

) ( ) (

) (03H)

A transmission message consists of [STX], [Unit Address], [;], [Command], [:], [Parameter], and [ETX], [Unit Address] is
expressed as [ADuuu] where uuu is in the range of 001 through 099 in decimal form to identify the unit number of the Monitor.

• Command Table

The transmission command consists of three letters followed by the unit address.

Item

Command (ASCII)

Parameter (ASCII)

Volume Control

VRA : n

n=:+ Value Increment

n=- Value Decrement

Brightness Control

VRB : n

n=+ Value Increment

n=- Value Decrement

Contrast Control

VRC ; n

n=+ Value Increment

n=- Value Decrement

Sharpness Control

VRS : n

n=+ Value Increment

n=- Value Decrement

Color Control

VRO : n

n=+ Value Increment

n=- Value Decrement

Tint Control

VRT: n

n^+ Value Increment

n=- Value Decrement

AFC Control

VRFi n

n=0 SHORT

n=1 LONG

3.58 MHz Trap Setting

VRP : n

n=0 OFF

n=1 ON

STANDBY ON Setting

MSB : n

n=0 IGNORE

n=l MODE 1

n=2 MODE 2

STANDBY Button Selection

OSB : n

n=0 Normal Display

n=1 Standby Mode 1

n=2 Standby Mode 2

Input Channel Display

DCH ; n

n=0 OFF
n=1 ON

Language Setting

DLA : n

n=0 ENGLISH

n=1 FRANÇAIS

n=2 ESPAÑOL