To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door

control.

• Connect only to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of

reach of children at a minimum height of 5 feet, and
away from all moving parts of door.

• NEVER permit children to operate or play with door

control push buttons or remote control transmitters.

• Activate door ONLY when it can be seen clearly, is

properly adjusted, and there are no obstructions to door
travel.

• ALWAYS keep garage door in sight until completely

closed. NEVER permit anyone to cross path of closing
garage door.

WARNING

Dry Wall Anchors

Insulated
Staples

6ABx1-1/2" Screw
Lighted Door Control Button

HARDWARE SHOWN ACTUAL SIZE

18

INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of the door at a
minimum height of 5 feet where small children
cannot reach, and away from moving parts of the
door and door hardware. If installing into drywall, drill
5/32" holes and use anchors provided.

• Strip 1/4" of insulation from one end of bell wire

and connect to the two screw terminals on back of
door control by color: white to 2 and white/red to 1.

• Fasten the Lighted Door Control Button securely

with 6ABx1-1/2" self-tapping screws.

• Run bell wire up wall and across ceiling to motor

unit. Use insulated staples to secure wire in
several places. Do not pierce wire with a staple,
creating a short or open circuit.

• Connect bell wire to the opener terminal screws as

follows: white to 2 and white/red to 1.

• Use tacks or staples to permanently attach

entrapment warning label to wall near door control,
and manual release/safety reverse test label in a
prominent location on inside of garage door.

NOTE: DO NOT connect the power and operate the
opener at this time. The trolley will travel to the full
open position but will not return to the close position
until the sensor beam is connected and properly
aligned. See Safety Reversing Sensor Instructions
beginning on page 21.

Opener
Terminal
Screws

Bell Wire

Antenna

BACK PANEL

Terminal Screws

Bell Wire

WHT

RED

KG

KG

1

3

9

7

5

1

3

9

7

5

2

3

1

-2

-1

Lighted
Door Control
Button

Advertising