Copyright © 2011, Tjernlund Products, Inc. All rights reserved.

P/N 8504160

REV. A 3/11

RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION!

THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSON-
NEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE
INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE
TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT,
SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON
MONOXIDE POISONING, EXPLOSION, PERSONAL INJURY OR PROPERTY DAMAGE. THIS INSTAL-
LATION MANUAL DOES NOT CONTAIN ANY SYSTEM DESIGN DOCUMENTATION.

!

DO NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN

A SAFE PLACE ON JOB SITE FOR FUTURE REFERENCE.

RT750 & RT1500

For Gas & Oil Applications

RT750H & RT1500H

For Solid Fuel Applications

Rooftop Inducers

FOR NATURAL GAS, LP, OIL-FIRED,
SOLID FUEL HEATING APPLIANCES
AND GENERAL VENTILATION

TJERNLUND PRODUCTS, INC.

1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com

Rooftop Inducers are tested and Listed to UL
Standard 378 for Draft Equipment
Rated up to 1000° F

Rooftop Inducers are tested and Listed to
ANSI/UL 705-2004 Power Ventilators

Rooftop Inducers are tested and Listed to CAN3-B255-M81
for Mechanical Flue-Gas Exhausters
Restricted to Non-Solid Fuel applications only under the
scope of standard CAN3-B255-M81
Rated up to 575° F / 300° C in Canada

For non-condensing applications only. Not suitable for Side Wall terminations.

IMPORTANT: Use of this product could cause flues to reverse (back-draft) on other heating equipment with-
in the same structure if adequate make-up air is not provided. Check for flue gas spillage of atmospheri-
cally vented heaters after rooftop Inducer installation and always have working carbon monoxide detectors
installed per the CO detector manufacturer’s instructions and local codes. Make-up / combustion air fans
are available from Tjernlund if necessary.