CCI Thermal Technologies SHMK - Swivel Hanging Mounting Kit Manuel d'utilisation

Chauffe-eau CCI Thermal Technologies

Advertising
background image

CONTENTS

Item

Qty. Description

2 Angle Hanger

2 Connector Hanger

2 Adaptor Hanger

5 Bolt, 1/2 UNC x 1-1/4

4 Nut, 1/2 UNC

5 Lock Washer, 1/2”

1 Mtg Attach Assy Bracket

1 Swivel Mtg Attach Assy

3 Flat Washer, 1/2”

STEP 4

Screw Hanger Assemblies to

the Swivel Mtg Attach Assy

.

Swivel Hanging Mounting Kit Installation Instructions

For Heat Exchanger Unit Heaters

(En français à l’endos.)

STEP 3

Bolt Mtg Attach Assy Bracket

to the heater using 1/2

UNC x 1-1/4 bolts, lock

washers, flat washers, and 1/2

UNC nuts.

STEP 2

Screw one Connector Hanger

and one Adaptor Hanger

onto each steel pipe until

tight (minimum of 5 turns

each).

Pipe cut length = Distance

from support structure to top

of heater

LESS 9-3/8” (238mm)

STEP 1

Fasten Angle Hangers

to a surface

or structure that will support the heater’s

weight using the installer supplied

fasteners. Refer to the owner’s manual

for the heater’s weight.

Installer required to supply:

a) a method of fastening the Angle Hangers

to the supporting structure that is at least as strong as four 3/8”

diameter, grade 5 bolts (see step 1) and,

b) two pieces of 1/2”, schedule 40 or heavier, steel pipe cut to suit required installation length and threaded at both

ends (see step 2).

Check that your heater model number corresponds to the model number shown on the mounting kit carton.

Printed in Canada. Copyright 2008. All rights reserved.

Part No. 5756-2

STEP 5

Hang assembly from Angle

Hangers ¿ using two 1/2 UNC

x 1-1/4 bolts, lock washers,

and nuts.

STEP 6

Connector Hanger

must be

hung on the inside of Angle

Hanger

as shown. Rotate

Connector Hanger

to align

with Angle Hanger

Do not

back off more than 3/4 turns.

Bolt the Swivel Mtg Attach

Assy

to the Mtg Attach

Assy Bracket

using a 1/2

UNC x 1-1/4 bolt, lock washer,

and flat washer. Swivel heater

to desired orientation and

secure in place.

 

Support

structure



Heater

may be

rotated as

indicated

by arrows

1/2” Sch. 40, or

heavier Steel pipe

10-1/8”

(258 mm)

4-1/2”

(114 mm)

Support structure

Installer supplied

fasteners

WARNING:

If the heater is installed on a structure that is to be transported, provide additional support for the

heater during transit. The suspended weight should not exceed 300lbs (136kg). Refer to the

owner`s manual for mounting specifications and conditions.

Advertising