Whirlpool W10150612A Manuel d'utilisation

Page 10

Advertising
background image

10

1. Loosen or remove center silver-colored terminal block screw.
2. Place the hooked end of the neutral wire (white or center wire)

of power supply cable under the center screw of terminal
block (hook facing right). Squeeze hooked end together.
Tighten screw.

3. Place the hooked ends of the other power supply cable wires

under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.

4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

6. You have completed your electrical connections. Now go to

“Venting Requirements.”

Optional 3-wire connection

Use for direct wire or power supply cord where local codes do
not permit connecting cabinet-ground conductor to neutral
wire.

1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor

screw. Connect neutral ground wire and the neutral wire (white
or center wire) of power supply cord/cable under center,
silver-colored terminal block screw. Tighten screw.

3. Connect the other wires to outer terminal block screws.

Tighten screws.

4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

6. Connect a separate copper ground wire from the external

ground conductor screw to an adequate ground.

A. Neutral ground wire
B. External ground conductor screw

C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)

E.

³⁄₄

" (1.9 cm) UL listed strain relief

B

C

D

E

A

A. External ground conductor screw
B. Neutral ground wire

C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)

E. ¾" (1.9 cm) UL listed strain relief

F. Grounding path determined by a qualified electrician

A

B

C

D

E

F

Advertising