3. Use a combination wrench and pliers to attach the flexible

connector to the adapters. Check that connector is not
kinked.

Complete Connection

1. Locate gas pressure regulator in the back of the range.

IMPORTANT: Do not remove the gas pressure regulator.

2. Check that the gas pressure regulator shutoff valve is in the

“ON” position.

IMPORTANT: The factory default setting is the “ON” position. If
the range does not work, verify that the valve is in the “ON”
position.

3. Open the manual shutoff valve in the gas supply line. The

valve is open when the handle is parallel to the gas pipe.

4. Test all connections by brushing on an approved

noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.

5. Remove cooktop burner caps and grates from parts

package. Align notches in burner caps with pins in burner
base. Burner caps should be level when properly positioned.
If burner caps are not properly positioned, surface burners
will not light. Place burners, burner caps and grates on the
cooktop.

6. Plug into a grounded 3 prong outlet.

Verify Anti-Tip Bracket Is Installed and

Engaged

1. Place the outside of your foot against the bottom front of the

broiler, and grasp the lower right or left side of the control
panel as shown.

NOTE: If your countertop is mounted with a backsplash, it
may be necessary to grasp the range higher than is shown in
the illustration.

2. Slowly attempt to tilt the range forward.

If you encounter immediate resistance, the range foot is
engaged in the anti-tip bracket.

3. If the rear of the range lifts more than ½" (1.3 cm) off the floor

without resistance, stop tilting the range and lower it gently
back to the floor. The range foot is not engaged in the anti-tip
bracket.

A. Pressure regulator

connection fitting

B. Use pipe-joint compound.

C. Adapter
D. Flexible connector

E. Adapter

F. Use pipe-joint compound.

G. Manual shutoff valve

H. ½" or ¾" gas pipe

A. Gas pressure regulator

A.

On

position

B.

Off

position

A. Closed valve
B. Open valve

C

E

G

H

A

D

F

B

A

A

B

A

B

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING

Advertising