Diagnostic chart – Controlled Products Systems Group 3265-267H Manuel d'utilisation

Page 30

Advertising
background image

Bell Wire

Safety Reversing Sensor

Diagnostics
Located On
Motor Unit

LED or
Diagnostic
LED

“Learn”
Button

30

Installed

Safety Reversing

Sensor

Your garage door opener is programmed with self-diagnostic
capabilities. The “Learn” button/diagnostic LED will flash a
number of times then pause signifying it has found a potential
issue. Consult Diagnostic Chart below.

Diagnostic Chart

Symptom: One or both of the Indicator lights on the safety sensors do
not glow steady.
• Inspect sensor wires for a short (staple in wire), correct wiring polarity

(black/white wires reversed), broken or disconnected wires, replace/attach
as needed.

• Disconnect all wires from back of motor unit.
• Remove sensors from brackets and shorten sensor wires to 1-2 ft. (30-60 cm)

from back each of sensor.

• Reattach sending eye to motor unit using shortened wires. If sending eye

indicator light glows steadily, attach the receiving eye.

• Align sensors, if the indicator lights glow replace the wires for the sensors. If

the sensor indicator lights do not light, replace the safety sensors.

Symptom: LED is not lit on door control.
• Inspect door control/wires for a short (staple in wire), replace as needed.
• Disconnect wires at door control, touch wires together. If motor unit activates,

replace door control.

• If motor unit does not activate, disconnect door control wires from motor unit.

Momentarily short across red and white terminals with jumper wire. If motor
unit activates, replace door control wires.

Symptom: Sending indicator light glows steadily, receiving indicator light
is dim or flashing.
• Realign receiving eye sensor, clean lens and secure brackets.
• Verify door track is firmly secured to wall and does not move.

Symptom: Motor has over heated; the motor unit does not operate or
trolley is stuck on stop bolt = Motor unit hums briefly; RPM Sensor =
Short travel 6-8" (15-20 cm).
• Unplug unit to reset. Try to operate motor unit, check diagnostic code.
• If it is still flashing 5 times and motor unit moves 6-8" (15-20 cm), replace RPM

sensor.

• If motor unit doesn’t operate, motor unit is overheated. Wait 30 minutes and

retry. If motor unit still will not operate replace logic board.

Symptom: Motor unit doesn’t operate.
• Replace logic board because motor rarely fails.

Motor Circuit Failure.
Replace Receiver
Logic Board.

Motor overheated or
possible RPM sensor
failure. Unplug to reset.

Safety reversing sensors
slightly misaligned
(dim or flashing LED).

Door control or
wire shorted.

Safety reversing sensors
wire shorted or
black/white wire reversed.

Safety reversing sensors
wire open (broken or
disconnected).

1 FLASH

2 FLASHES

3 FLASHES

4 FLASHES

5 FLASHES

6 FLASHES

OR