INSTALLATION STEP 7

Install the Light

• Press the release tabs on both sides of lens. Gently

rotate lens back and downward until the lens hinge is in
the fully open position. Do not remove the lens.

• Install up to a 100 watt maximum light bulb in each

socket. Light bulb size should be A19, standard neck
only. The light will turn ON and remain lit for
approximately 4-1/2 minutes when power is connected.
Then the lights will turn OFF.

• Reverse the procedure to close the lens.

• If the bulbs burn out prematurely due to vibration,

replace with a Garage Door Opener bulb.

• Use A19, standard neck garage door opener bulbs for

replacement.

NOTE: Use only standard light bulbs. The use of short
neck or speciality light bulbs may overheat the endpanel
or light socket.

INSTALLATION STEP 8

Attach the Emergency Release Rope
and Handle

• Thread one end of the rope through the hole in the top

of the red handle so “NOTICE” reads right side up as
shown. Secure with an overhand knot at least 1"
(2.5 cm) from the end of the rope to prevent slipping.

• Thread the other end of the rope through the hole in the

release arm of the outer trolley.

• Adjust rope length so the handle is 6 feet (1.83 m)

above the floor. Ensure that the rope and handle clear
the tops of all vehicles to avoid entanglement. Secure
with an overhand knot.

NOTE: If it is necessary to cut the rope, heat seal the cut
end with a match or lighter to prevent unraveling.

Trolley

NOTICE

Overhand
Knot

Emergency
Release Handle

Rope

Trolley
Release Arm

To prevent possible SERIOUS INJURY or DEATH from a falling
garage door:
• If possible, use emergency release handle to disengage

trolley ONLY when garage door is CLOSED. Weak or broken
springs or unbalanced door could result in an open door
falling rapidly and/or unexpectedly.

• NEVER use emergency release handle unless garage

doorway is clear of persons and obstructions.

• NEVER use handle to pull door open or closed. If rope knot

becomes untied, you could fall.

Lens
Hinge

100 Watt (Max)
Standard Light Bulb

Release Tab

100 Watt (Max)
Standard Light Bulb

To prevent possible OVERHEATING of the endpanel or light
socket:
• DO NOT use short neck or specialty light bulbs.
• DO NOT use halogen bulbs. Use ONLY incandescent.
To prevent damage to the opener:
• DO NOT use bulbs larger than 100W.
• ONLY use A19 size bulbs.