Burner and nozzle specifications – Hotpoint Ariston TD 640 S (ICE) IX-HA User Manual

Page 16

Advertising
background image

GB

16

Burner and nozzle specifications

Table 1

Liquid Gas

Natural Gas

Burner

Diameter

(mm)

Thermal power

kW (p.c.s.*)

By-Pass

1/100

(mm)

Nozzle

1/100

Flow*

g/h

Nozzle

1/100

Flow*

l/h

Nomin.

Ridot.

(1)

(mm)

***

**

(mm)

Fast (R)

100

3,00

0,70

41

39

86

218

214

116

286

Reduced Fast
(RR)

100

2,60

0,70

41

39

80

189

186

110

248

Ultrarapid (UR)

100

3,40

0,70

41

39

91

247

243

123

324

Semi Fast (S)

75

1,65

0.40

30

28

64

120

118

96

157

Auxiliary (A)

55

1,00

0,40

30

28

50

73

71

79

95

Mini WOK (MW)

110

3,50

1,30

-

57

94

254

250

138

333

Supply
Pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20
35

37
25
45

20

17

25

*

At 15°C and 1013 mbar-dry gas

**

Propane

P.C.S. = 50.37 MJ/kg.

***

Butane

P.C.S. = 49.47 MJ/kg.

Natural

P.C.S. = 37.78 MJ/m

3

(1) Only for appliances with the security device.

Ø 145

S

R

S

A

S

R

S

A

S

RR

MW

A

UR

RR

S

S

A

MW

RR

S

S

TD 750 S IX/HA

TD 751 S GH/HA
TQ 751 S GH/HA
TZ 751 S /HA

TD 640 IX/HA
TD 640 S IX/HA
TQ 640 S GH/HA
TZ 640 S /HA

TD 641 S IX/HA

TD 631 S IX/HA