Warning, Connect vent system, Make electrical connection – Whirlpool W10018010 Manuel d'utilisation

Page 8

Advertising
background image

8

2. Level the blower housing with leveling screws in mounting

hooks, using a level across bottom of blower housing.

3. Remove the metal grease filter and secure the blower

housing with one screw in the bottom hole located in the rear
of the blower.

Connect Vent System

Vented Installations Only

1. Fit vent system over transition piece.

2. Seal connection with clamps.

Non-vented (recirculating) Installation

1. Assemble the 3 parts of the deflector with 2 - 3.5 x 6.5 screws

provided. The assembled deflector should be sized to fit the
width of the vent cover bracket installed earlier.

2. Connect the deflector to the vent cover bracket using

4 - 3.5 x 6.5 screws provided.

3. Measure length of 8" (20.3 cm) vent needed to connect the

transition to the deflector.

NOTE: Vent should fit up inside deflector a minimum of
1" (2.5 cm).

4. Install vent between the transition and the deflector.

5. Seal all connections with clamps.

Make Electrical Connection

1. Disconnect power.

2. Remove terminal box cover.

3. Remove the knockout.

4. Install the UL listed or CSA approved strain relief.

A. Rear of blower housing
B. Bottom 5 x 35 screw hole

A. Vent cover bracket width
B. Deflector

C. 3.5 x 6.5 mm screws

A. Vent cover bracket
B. 3.5 x 6.5 mm screws

A

B

A

B

C

A

B

A. Knockout
B. Terminal box cover

A. ½" conduit
B. Terminal box cover

C. UL listed or CSA approved strain relief
D. Green (or bare) wire connected to yellow-green wire

E. White wires
F. Black wires

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

A

B

A

B

C

D

E

F