Advertising
background image

3. Drill

³⁄₈" (9.5 mm) holes for wall anchors and insert anchors

flush with the wall.

4. Attach vent cover support bracket to wall.

Installation locations with reduced ceiling heights.

For vented and non-vented (recirculating) installations, the vent
hood is installed using the upper vent cover (26" [66.0 cm]) plus
a

¹⁄₄" (6.4 mm) thick wood filler.

1. For the vent cover to slide down and engage the top of

the hood, the vent cover bracket must be installed

¹⁄₄"

(6.4 mm) below the ceiling.

2. The remaining space above the vent cover can be filled

with a

¹⁄₄" (6.4 mm) thick piece of plywood cut to the inside

cross section of the chimney cover and finished to match
the ceiling.

3. Cut the self-adhesive rubber tape supplied with the hood

in 4 identical pieces. Attach two pieces of tape to each
side of the support bracket.

Vent Installations

Vented installations

Install transition on top of hood (if removed for shipping) with 2
sheet metal screws.

Non-vented (recirculating) installations

1. Install transition on top of hood (if removed for shipping) with

2 sheet metal screws.

2. Attach the vent cover ceiling bracket to the deflector with two

screws provided.

3. Connect the deflector to the transition with 6" (15.2 cm)

round vent.

6. Tape template in place aligning the template centerline and

bottom of template with hood bottom line and with the
centerline marked on the wall.

7. Mark centers of the 6 fastener locations through the template

to the wall.

IMPORTANT: At least two of the screws must be installed into
wood.

Remove the template.

8. Drill

⁷⁄₆₄" (2.75 mm) pilot holes at all locations where screws

are being installed into wood.

9. Determine and make all necessary cuts in the wall for the vent

system. Install the vent system before installing the hood. See
“Venting Requirements” section.

10. Determine the required height for the

¹⁄₂" conduit and drill a

1

¹⁄₄" (3 cm) hole at this location.

11. Run wire through the

¹⁄₂" conduit according the National

Electrical Code or CSA Standards and local codes and
ordinances. There must be enough

¹⁄₂" conduit and wires from

the fused disconnect (or circuit breaker) box to make the
connection in the hood’s electrical terminal box.

12. Use caulk to seal all openings.

NOTE: Do not turn on power until installation is complete.

13. Attach 2 mounting hooks to the wall at locations marked on

the template.

Vent Cover Support Bracket Installation

Installations using telescoping upper and lower vent cover
assembly.

1. Position vent cover bracket on wall about

¹⁄₈" (3 mm) away

from the ceiling.

2. Mark the hole locations.

7

A

B

B

C

D

A. Centerline
B. Mounting hook location
C. Fastener locations
D. Mounting height reference

A

B

A. Mounting hooks
B. Centerline on wall

A

B

A. Vent cover support bracket
B. Centerline on wall

A

A. Rubber tape

A

A. Vent cover support bracket
B. Deflector

B