4

Product Dimensions

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.

Grounded electrical outlet is required. See “Electrical
requirements” section.

The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) installations see “Non-vented
(recirculating) installations” in “Prepare Mounting Location”
section.

All openings in ceiling and wall where canopy hood will be
installed must be sealed.

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools
listed here.

Tools needed:

level

drill with 1

¹⁄₄" (3 cm), ³⁄₈" (9.5 mm), ⁷⁄₆₄" (2.75 mm) and

¹⁄₈" (3 mm) drill bits

pencil

wire stripper or utility knife

measuring tape or ruler

pliers

caulking gun and weatherproof caulking compound

duct tape

jig saw or keyhole saw

flat blade screwdriver

metal snips

Phillips screwdriver

Parts needed:

1 x

¹⁄₂" conduit

1 wall or roof cap

metal vent system

2 charcoal filters – for non-vented (recirculating)
installations only

Parts supplied:

Remove parts from packages. Check that all parts were included.

hood canopy assembly with ventilator and light bulbs installed

deflector for non-vented (recirculating) installations

plastic transition with back draft dampers installed

Installation Instructions and Use & Care Guide

filter(s) – depending on model and size

screws and drywall anchors

2 mounting hooks

vent cover support bracket

mounting template

2 piece vent cover

rubber tape

INSTALLATION REQUIREMENTS

8"

(20.3 cm)

16

³⁄₄

"

(42.5 cm)

upper vent

cover

lower vent

cover

20

³⁄₁₆

"

(51.3 cm)

30" (76.2 cm) or

36" (91.4 cm)

9

⁵⁄₈

" (24.4 cm) min.

26" (66.0 cm) max.

26" (66.0 cm)

min.

42

³⁄₈

" (107.6 cm)

max.

6

³⁄₄

"

(17.1 cm)

9

¹⁄₂

"

(24.1 cm)

NOTE: For reduced ceiling height vented and non-vented (recirculating)

installations, only the upper vent cover, which is 26" (66.0 cm), is used.