8

Wood Frame Installation - Style 2
(optional before drywall installation)

1. Construct wood wall framing so that it is flush with interior

surface of wall studs. The framing must be centered over the
installation location. The height of the framing must allow for
the mounting bracket to be secured to the framing within the
dimensions shown.

2. After the wall surface is finished, drill two

⁵⁄₃₂" (4 mm) pilot

holes.

3. Install the mounting bracket to the frame using

two 4.8 x 38 mm pan head mounting screws.

Install Flue Mounting Bracket

1. Assemble the flue mounting bracket by attaching the 2 side

brackets to the center bracket using the 2 flat head bracket
screws provided. Adjust outside width as shown.

2. Center the mounting bracket directly over the range hood

location.

3. Drill two

⁵⁄₁₆" pilot holes for drywall anchors.

4. Install drywall anchors.

5. Attach the flue mounting bracket to the ceiling using

two 4.8 x 38 mm pan head mounting screws.

Prepare Range Hood

NOTE: Remove the plastic film from all exterior surfaces of the
hood and decorative flues, prior to final installation.

Vented Installation

Install the damper into the duct connector of the range hood.

Non-vented (recirculating) Installation

Damper supplied with hood is not required in a non-vented
(recirculating) installation. Install the 5" (12.7 cm) to 6" (15.2 cm)
adapter supplied with the Charcoal Filter Kit, Part Number
8212566. See “Assistance or Service” section to order.

A. 5

¹⁄₁₆" (12.9 cm)

B. 38

¹⁄₁₆" to 44¹⁄₁₆" (96.7 cm to 111.9 cm) above cooktop

C. Centerline

A. 3.9 x 5.7 mm flat head bracket screws
B. 9

¹³⁄₁₆" (24.9 cm)

A

B

C

A

B

A. Flue mounting bracket
B. Hood mounting bracket

C. Centerline
D. Cooktop surface

A. Damper
B. Duct connector

A. 5" (12.7 cm) to 6" (15.2 cm) adapter
B. Blower collar

A

B

C

D

B

A

B

A