To remove metal filters:

1. Turn off blower and lights.

2. Push handle toward the rear and pull downward.

Pull filter toward the front.

To replace the metal grease filter:

1. Insert back edge of filter into the rear channel of the filter

opening.

2. Push handle toward the rear and push the filter up.

3. Push filter toward the front and insert into the front channel.

Charcoal Filters - For non-vented (recirculating) installations

The charcoal filter should be changed every 6 months.

To remove the charcoal filter:

Press inward on the clamp and rotate the filter downward until
the 2 tabs can be removed from the housing.

Replacing a Halogen Lamp

IMPORTANT: To avoid blowing internal fuse, do not use
replacement bulb larger than 12-volt, 20-watt.

Turn off the range hood and allow the halogen lamps to cool.
Replace bulb by using a tissue to handle bulb or while wearing
cotton gloves. Do not touch bulb with bare fingers.

If new lights do not operate, make sure the lamps are inserted
correctly before calling service.

1. Disconnect power or unplug the range hood.

2. Use a flat-blade screwdriver and gently pry the light cover

loose.

3. Remove the burned out lamp.

4. Replace lamp with a 12-volt, 20-watt maximum, halogen

lamp made for a G-4 base. Use a tissue to handle the lamp or
wear cotton gloves. Do not touch the lamp with bare fingers.

5. Replace the light cover.

6. Reconnect power or plug in range hood.

Fuse Replacement

1. Disconnect power or unplug the range hood.

2. Remove the decorative flue.

3. Open the fuse box by removing screw.

4. Replace with the same type of fuse (5 x 20 mm, 4A, 125V).

A. Metal grease filters

A. Tabs
B. Clamp

A

B

A

A. Decorative flue
B. Fuse box

C. Fuse

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

A

B

C