Warning – Whirlpool W10029770A Manuel d'utilisation

Page 11

Advertising
background image

11

Non-vented (recirculating) Installation - Style 2

IMPORTANT: For this installation, you will need Charcoal Filter
Kit Part Number 8212566.

1. To determine the length of flexible duct that is necessary

when the deflector is positioned near the ceiling, measure the
distance from the adapter to the deflector.

2. Attach the flexible metal duct to the 5" (12.7 cm) adapter.

Seal connection with vent clamp.

3. Assemble the deflector to the flexible metal duct.

4. Attach the duct to the deflector’s connector with vent clamps.

5. Slide the lower decorative flue into the recessed area of the

range hood top.

6. Slide the upper decorative flue down inside the lower

decorative flue.

NOTE: The upper decorative flue vents must be visible.

7. Secure the deflector to the upper decorative flue with 4 flat

head screws (included in charcoal filter kit).

8. Plug into a grounded 3 prong outlet.

9. Raise the upper decorative flue until the holes align with the

holes in the flue mounting bracket.

10. Mount the decorative flue to the flue mounting bracket with

two 3.9 x 9.5 mm mounting screws.

A. Deflector
B. Adapter

C. Distance from adapter to deflector

A. 5" (12.7 cm) flexible metal duct
B. Vent clamp location

C. Blower collar

A. Lower decorative flue
B. Recessed area

A

B

C

A

B

C

A

B

A. Deflector
B. Four flat head screws

C. Upper decorative flue

A. Flue mounting bracket
B. 3.9 x 9.5 mm mounting screws

A

B

C

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING