Vent system requirements, Interior-mounted vent motor, Installation requirements – Whirlpool GZ7930XGS0 Manuel d'utilisation

Page 6: Maximum length of vent system, Determining the length of system you need

Advertising
background image

6

Vent system
requirements

Venting system must terminate to
the outside.

Do not terminate the vent system
in an attic or other enclosed area.

Do not use 4" (10.2 cm) laundry-
type wall caps

Do not use plastic or metal foil
vent.

Vent work needed for installation
is not supplied.

Wall cap is not provided with
interior-mounted motor.

Determine which venting method
to use. Vent system can extend
through either the wall or roof.

The length of vent system and
number of elbows should be kept
to a minimum to provide efficient
performance.

The size of the vent should be
uniform.

Do not install two elbows
together.

Use duct tape to seal all joints in
the vent system.

Use caulking tape to seal the
exterior wall or floor opening
around cap.

Do not cut joist or stud. If vent
cutout falls over a joist or stud, a
supporting frame must be
constructed.

Flexible metal vent is not
recommended. If it is used,
calculate each foot of flexible vent
as two feet of rigid metal vent.
Flexible elbows count twice as
much as standard elbows.

NOTE: Make sure there is proper
clearance within the wall or floor
before making exhaust vent
cutouts.

Recommended vent system
length: For either interior-mounted
or exterior-mounted blower
installations, vent system length
should not exceed the maximum
lengths listed in the “Maximum
length of vent system” chart. (See
this page for Interior-mounted
vent motor; page 9 for exterior-
mounted vent motor.)

Interior-mounted vent motor

Installation requirements

Island location

Built-in cabinet locations

down vent

down vent

rear vent

left vent

right vent

Vent system installed under a
concrete slab using PVC sewer pipe.

wall
cap

6" (15.2 cm)
round PVC
coupling

6" (15.2 cm)

round PVC

sewer pipe

6" (15.2 cm) round metal vent

Tightly pack
gravel or sand
completely
around pipe.

transition

6" (15.2 cm)

round metal

vent

6" (15.2 cm)

round PVC

coupling

concrete
slab

6" (15.2 cm)
round PVC
sewer pipe

6" (15.2 cm)
round 90°
PVC sewer
pipe elbow

6" (15.2 cm)
round 90°
PVC sewer
pipe elbow

16" (40.6 cm)

maximum

12" (30.5 cm)

minimum

SBCCI

wall
cap

window
well

6" (15.2 cm)
min.

Tightly pack
gravel or sand
completely
around pipe

.

transition

6" (15.2 cm)
round metal vent

6" (15.2 cm)
round PVC
coupling

6" (15.2 cm)
round sewer
pipe

6" (15.2 cm) round
90° PVC sewer
pipe elbow

concrete
slab

6" (15.2 cm)
round PVC
coupling

12" (30.5 cm)

minimum

6" (15.2 cm) round
PVC sewer pipe

Optional vent system installed under
a concrete slab into a window well.

Do not vent a gas cooktop into
a window well.

SBCCI

Seal the space between the outside of
wall cap inlet inside of PVC coupling
with caulking metal.

Maximum length of vent
system

For best performance, use no more
than three 90° elbows. If more than
one elbow is used, make sure that
there is a minimum of 24" (61 cm)
of straight vent between any two
elbows. Do not install two elbows
together. It is recommended that
you use round vent instead of
rectangular vent, especially if
elbows are required. If rectangular
vent is required, it should be
transitioned to 6" (15.2 cm) round
vent as soon as possible.

Determining the length of

system you need:

To calculate the length of system
you need, add the equivalent feet
for each vent piece that will be
needed. See example for 6"
(15.2 cm) round vent system.

Vent

Length

6" (15.2 cm) round

35 feet (8.9 m)

3-1/4" x 10"

35 feet (8.9 m)

(8.3 cm x 25.4 cm)